140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J6C4-C50 from the 140G MCB series.
    Allen Bradley

    140G-J6C4-C50

    This circuit breaker features a J frame and is equipped with four poles. It can manage a current range of 50 A and is rated for insulation voltages up to 1000 V. The device can also withstand impulse

    Available
    Call
  • 140G-J6F4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J6F4-D10

    Engineered with four poles, this breaker operates in a current range of 100 Amps. It includes adjustable thermal and magnetic protection options, allowing for fine-tuning to specific applications. It

    Available
    Call
  • 140G-J6F4-D11 from the 140G MCB series.
    Allen Bradley

    140G-J6F4-D11

    This molded case circuit breaker operates within a current range of 110 A and is built with four poles. It boasts a rated insulation voltage of 1000V and can withstand impulse ratings of 8 kV. The uni

    Available
    Call
  • 140G-J6F4-D12 from the 140G MCB series.
    Allen Bradley

    140G-J6F4-D12

    This circuit breaker features four poles and operates with an adjustable thermal and magnetic protection system. It is capable of managing a current range of 120 A and has an interrupting rating of 65

    Available
    Call
  • 140G-JC6H3-D15 from the 140G MCB series.
    Allen Bradley

    140G-JC6H3-D15

    This molded case circuit breaker features a JC frame and operates within a current range of 150 Amps. It has a rated insulation voltage of 1000 Volts and withstands impulse voltages up to 8 kV. Weighi

    Available
    Call
  • 140G-JTC4-C63 from the 140G MCB series.
    Allen Bradley

    140G-JTC4-C63

    This molded case circuit breaker includes four poles and a J frame, optimizing its adaptability in various installations. It provides robust protection with fixed thermal and magnetic settings and is

    Available
    Call
  • 140G-JTF4-C80 from the 140G MCB series.
    Allen Bradley

    140G-JTF4-C80

    This circuit breaker is built with a J frame structure. It supports an insulation voltage rating of 1000 volts and can endure impulse voltages of 8 kV. Weighing 7.72 pounds, it is recognized for its d

    Available
    Call
  • 140G-JTH3-D15 from the 140G MCB series.
    Allen Bradley

    140G-JTH3-D15

    Offering a current range of 150 A, the 140G-JTH3-D15 is capable of operating under a rated insulation voltage of 1000 volts. Its impulse withstand rating reaches 8 kV, presenting robust durability in

    From $1,145
    In Stock Ships Today
  • 140G-KC6H3-D30 from the 140G MCB series.
    Allen Bradley

    140G-KC6H3-D30

    This circuit breaker, designed with a KC frame, supports a rated current of 300 Amps. It can manage insulation voltage levels of up to 1000 V and withstand impulse voltages of 8 kV. The unit weighs 7.

    Available
    Call
  • 140G-M0I3-D60 from the 140G MCB series.
    Allen Bradley

    140G-M0I3-D60

    Rated for 800 Amps, the 140G-M0I3-D60 breaker supports a current range of 600 A. The device has a frame type of M and handles insulation voltage levels up to 1000 V. Its rated impulse withstand voltag

    Available
    Call
Showing 1,051-1,060 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.