140G-I2C4-C63
This circuit breaker operates with a current range of 63 A and is equipped with fixed thermal and magnetic protection systems. Designed with four poles, it is capable of supporting a rated insulation
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker operates with a current range of 63 A and is equipped with fixed thermal and magnetic protection systems. Designed with four poles, it is capable of supporting a rated insulation
This circuit breaker operates at a maximum rated insulation voltage of 800 volts with a thermal trip setting of 70 A and a magnetic trip setting reaching 700 A. The frame type is classified as Frame I
This circuit breaker is designed to operate in environments with maximum storage and operating humidity of 80% (non-condensing). It supports installation at altitudes up to 1000 meters above sea level
As part of the J frame series, this circuit breaker is designed with electronic LSIG protection. It accommodates rated current levels of up to 40 A and is rated for up to 1000 volts of insulation volt
This four-pole circuit breaker supports a current rating of 70 A and a maximum current of 250 A. It is rated for an insulation voltage of 1000 V, and its impulse withstand voltage rating is 8 kV. It i
This molded case circuit breaker operates with a standard current rating of 120 A and is configured with four poles. It employs adjustable thermal and magnetic protection technology to ensure reliable
This molded-case circuit breaker features four poles and handles 200 A of rated current and 250 A of maximum current. It is rated for 1000 V of insulation voltage and can withstand impulse voltages of
This circuit breaker has a J-frame and operates with four poles. It supports a rated current of 40 A and a maximum current of 250 A and is rated for up to 1000 V of insulation voltage. Furthermore, it
This four-pole circuit breaker operates with 63 A of rated current and 250 A of maximum current, offering reliable performance. It's rated for an insulation voltage of up to 1000 volts and can withsta
This circuit breaker is designed with fixed thermal and magnetic protection mechanisms. It operates with 70 A of rated current and 250 A of maximum current and is rated for an interrupting capacity of
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.