140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-JC0C3-C35 from the 140G MCB series.
    Allen Bradley

    140G-JC0C3-C35

    Operating within a current range of 35 Amps, this device features fixed thermal and fixed magnetic protection. It also has a rated insulation voltage of 1000 volts and an impulse withstand rating of 8

    Available
    Call
  • 140G-JTC4-C30 from the 140G MCB series.
    Allen Bradley

    140G-JTC4-C30

    With a current range of 30 amps, the 140G-JTC4-C30 features four poles. It supports a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. The device weighs 7.72 po

    Available
    Call
  • 140G-JTH4-D10 from the 140G MCB series.
    Allen Bradley

    140G-JTH4-D10

    This molded case circuit breaker supports a current range of up to 100 A and operates at a rated insulation voltage of 1000 V. It is designed to withstand impulse voltages of 8 kV. Weighing 7.72 lbs,

    Available
    Call
  • 140G-K6K4-D30 from the 140G MCB series.
    Allen Bradley

    140G-K6K4-D30

    This molded case circuit breaker is equipped with electronic LSIG and MM protection. It operates with four poles and a rated current of 300 A. It supports a rated insulation voltage of 1000 volts and

    Available
    Call
  • 140G-M0H4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M0H4-D63

    This 140G series molded case circuit breaker features a frame classification of M and accommodates a range of 630 Amps. It operates under insulation voltage specifications of 1000 volts and can withst

    Available
    Call
  • 140G-M0K3-D63 from the 140G MCB series.
    Allen Bradley

    140G-M0K3-D63

    This device operates within a current range of up to 630 A and is designed for high voltage applications with a rated insulation voltage of 1000V. It incorporates Electronic LSIG protection and is cap

    Available
    Call
  • 140G-M5I3-D63 from the 140G MCB series.
    Allen Bradley

    140G-M5I3-D63

    As part of the M-frame series, this breaker operates effectively within a current range of 630 A. It has a rated insulation voltage of 1000V and withstands impulse voltages of up to 8 kV. Weighing 26.

    Available
    Call
  • 140G-M6I4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M6I4-D63

    This breaker features four poles and employs an electronic LSIG protection mechanism. It supports a current range of 630 Amps and operates within a rated insulation voltage of 1000 volts. Additionally

    Available
    Call
  • 140G-NS0I4-E12 from the 140G MCB series.
    Allen Bradley

    140G-NS0I4-E12

    This circuit breaker accommodates a maximum current range of 1200 A. It operates at a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. Weighing 27.56 pounds, it

    Available
    Call
  • 40G-K15I3-D30 from the 140G MCB series.
    Allen Bradley

    40G-K15I3-D30

    As part of Allen Bradley's 140G series, the 40G-K15I3-D30 handles up to 30 A within its specified current range. It maintains a rated insulation voltage of 1000 volts and is capable of enduring impuls

    Available
    Call
Showing 1,081-1,090 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.