140G-I3C3-C80
This circuit breaker features a frame size I and an interrupting rating of 35 kA. It supports a fixed thermal trip setting at 80 A, while the magnetic trip can handle up to 800 A. Its insulation volta
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker features a frame size I and an interrupting rating of 35 kA. It supports a fixed thermal trip setting at 80 A, while the magnetic trip can handle up to 800 A. Its insulation volta
This breaker has a J frame and includes four poles for adaptability. It supports a current rating of 150 A and up to 250 A of maximum current. Its insulation voltage is rated at 1000 V, and it can wit
This circuit breaker operates with four poles and supports adjustable thermal and magnetic protection options. It handles 250 Amps of current, 1000 volts of rated insulation voltage, and 8 kV of impul
Designed with a J frame, the 140G-J3F4-C80 model demonstrates adjustable thermal and magnetic protection types. Its current range is rated at 80 Amps, while it supports insulation rated up to 1000 Vol
Designed for robust performance, the 140G-J6C4-C63 model operates within a current range of up to 63 A. It provides fixed thermal and magnetic protection, ensuring effective circuit safety. With an in
Featuring a frame size denoted as J, this breaker operates with four poles. It maintains a current range of 60 A and is compatible with insulation up to 1000 V. The impulse withstand voltage is rated
This circuit breaker operates with a fixed thermal and magnetic protection type and has a current range of 32 amps. It maintains a rated insulation voltage of 1000 volts, with the ability to withstand
This circuit breaker employs fixed thermal and magnetic protection types and operates within a current range of 40 A. It has a rated insulation voltage of 1000 V and withstands impulse voltages of 8 k
This model features a JC frame and operates effectively within a current range of 50 Amps. It is built to withstand rated insulation voltages up to 1000 volts and can handle impulse withstand voltages
This model operates efficiently within a current range of 150 Amps. It features electronic LSIG protection and has a rated insulation voltage of 1000V, coupled with an impulse withstand rating of 8 kV
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.