140G-N6H4-E12
The 140G-N6H4-E12 circuit breaker, featuring a four-pole configuration, operates efficiently within a current range of 1200 A. With a rated insulation voltage of 1000V and impulse withstand voltage of
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
The 140G-N6H4-E12 circuit breaker, featuring a four-pole configuration, operates efficiently within a current range of 1200 A. With a rated insulation voltage of 1000V and impulse withstand voltage of
This circuit breaker includes four poles and operates effectively within a current range of 1200 A. It withstands rated insulation voltages of 1000 volts and impulse voltages of up to 8 kV. Weighing 2
This four-pole circuit breaker operates under an N frame designation and provides a current range of 1200 Amps. Its rated insulation voltage is up to 1000 volts, with the ability to withstand impulse
This device provides fixed thermal and magnetic protection, making it resilient against electrical surges. The 140G-H3C4-C63 operates within a current range of 63 Amps and is rated for insulation at 1
This molded case circuit breaker operates within a current range of 50 A and is designed with a frame categorized as HC. It is constructed to withstand an impressive rated insulation voltage of 1000 v
This unit is designated as a 4-pole circuit breaker that operates within a current range of 40 Amps. Rated for insulation voltages up to 1000 V, it can also withstand impulse voltages of 8 kV. The pro
This model supports a current range of 40 Amps and operates with an insulation voltage rating of 1000 Volts. It can withstand impulse voltages up to 8 kV. Weighing 7.72 pounds, this unit is designed f
This circuit breaker operates with four poles and utilizes fixed thermal and magnetic protection mechanisms. Its current handling is rated at 30 Amps, and it maintains a rated insulation voltage of 10
This circuit breaker features a JC frame type and can handle currents of up to 170 A. It operates at a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. Weighing 5.51 poun
This circuit breaker, featuring a JC frame, offers adjustable thermal and magnetic protection types. It operates within a current range of up to 200 A and has a rated insulation voltage of 1000 volts.
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.