140G-JC6F3-C90
This unit operates with an adjustable thermal and magnetic protection type, maintaining versatility across applications. The product supports a current range of 90 A and is rated for insulation voltag
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This unit operates with an adjustable thermal and magnetic protection type, maintaining versatility across applications. The product supports a current range of 90 A and is rated for insulation voltag
This circuit breaker operates with an adjustable thermal and magnetic protection mechanism for tailored performance. It accommodates a current range of 600 A, making it versatile for various electrica
The 140G-M5H4-D80 operates with a frame type M and is built to handle a maximum current range of 800 A. Its rated insulation voltage is 1000 volts, and it is capable of withstanding impulse voltages u
Designed for 630 A current range, the 140G-M5K3-D63 has a rated insulation voltage of 1000 volts. It can withstand impulse voltages of 8 kV, offering durability in electrical systems. Weighing 26.68 p
This circuit breaker is configured with four poles and features an electronic LSIG protection system. It can handle a current range up to 600 A and is rated for an insulation voltage of 1000 volts. Th
This circuit breaker features an NS frame design and incorporates four poles for operational versatility. Rated for an insulation voltage of 1000 volts and capable of withstanding impulse voltages up
This circuit breaker features four poles and operates within a current range of 1200 A. It is designed to handle a rated insulation voltage of 1000 volts and offers an impulse withstand rating of up t
Designed with an R frame type, this molded case circuit breaker offers an interrupting rating of 125 kA. It contains four poles and supports a maximum rated insulation voltage of 1000 volts, along wit
This circuit breaker is built on a G frame platform, offering robust protection via fixed thermal and fixed magnetic trip unit options. It operates effectively within a temperature range of -25 °C to
This component offers an operating temperature range from -40°C to 70°C and is capable of functioning at altitudes up to 2000 meters. It supports a humidity level of 95% (non-condensing) and includes
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.