140G-H2I4-C25
This unit offers an interrupting rating of 25 kA and operates with electronic LSIG protection. It accommodates a current range of 25 A, with a rated insulation voltage of 1000 V and a rated impulse wi
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This unit offers an interrupting rating of 25 kA and operates with electronic LSIG protection. It accommodates a current range of 25 A, with a rated insulation voltage of 1000 V and a rated impulse wi
This circuit breaker is equipped with 4 poles and utilizes electronic LSIG technology for comprehensive protection. It operates within a current range of up to 160 A. Moreover, it supports a rated ins
This molded case circuit breaker features a frame type designated as H. It is capable of sustaining 4 poles and provides protection via a breaker frame. With a rated insulation voltage of 1000 volts a
The 140G-H3H4-D12 circuit breaker is designed with an H frame and supports a current range of 120 A. It provides a rated insulation voltage of 1000 V and withstands impulse voltages up to 8 kV. The un
This molded case circuit breaker has four poles and operates with a rated current of 110 A and 250 A of maximum current. It utilizes adjustable thermal and magnetic protection options. The unit is rat
This circuit breaker features a J frame design and is equipped with four poles. Its operational current range reaches up to 32 A. The rated insulation voltage is 1000 V, and it is built to withstand i
The 140G-JC0X3 breaker has a JC frame and operates at a rated insulation voltage of 1000V. It can handle an impressive interrupting rating of 100 kA, ensuring reliable operation under fault conditions
The 140G-JTF4-D11 is engineered to manage a current range of 110 A. Accommodating up to 1000 V for rated insulation, it has an impulse withstand voltage capability of 8 kV. Designed for durability, it
With a frame size categorized as M, this unit operates at a rated insulation voltage of 1000 volts. It has a four-pole configuration and can withstand impulse voltages up to 8 kV. The breaker weighs 3
This 4-pole circuit breaker supports a current capacity of 1200 A, indicating excellent adaptability for diverse configurations. It is rated for an insulation voltage of 1000 V and can withstand impul
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.