Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-G2C4-C70

The 140G-G2C4-C70 is a molded case circuit breaker that operates at a frame size classified as G. Designed for a nominal current rating of 125 Amps, this device features four poles and ensures perform

Call
4.7

140G-H2C3-C63

The 140G-H2C3-C63 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

Available
4.7

140G-H2H4-C25

This device operates within a current capacity range of 25 Amps and has a rated insulation voltage of 1000 V. Additionally, it can withstand impulse voltages up to 8 kV. Weighing 3.53 pounds, it empha

Available
4.7

140G-K15F3-D30

The circuit breaker operates at 300 A of rated current and features adjustable thermal and magnetic protection options. It is rated for insulation voltages of up to 1000V and can withstand impulse vol

In Stock Ships Today
4.8

140G-MTK4-D60

This circuit breaker supports a current range of 600 A and is rated for an insulting voltage of 1000 volts. It can withstand impulse voltages of up to 8 kV. Weighing 33.29 lbs, it has a mechanical lif

In Stock Ships Today
4.7

140G-J0F3-D12

The 140G-J0F3-D12 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

Call
5.0

140G-JTI4-D25

This circuit breaker is structured with a J frame and contains four poles. It operates with a current rating of 250 Amps. It is rated for up to 100V of insulation voltage, and it can also endure impul

Call
4.6

140G-R12I3-E20-Z1

This circuit breaker is classified under frame R and features an interrupting rating of 125 kA. It also includes electronic LSIG protection for enhanced safety. The maximum current rating is 2000 A, a

Call
4.8

140G-H2F3-D16

This circuit breaker is designed with an H frame, supporting a current range of up to 160 Amps. It offers adjustable thermal and magnetic protection mechanisms. The rated insulation voltage is 1000 Vo

Call
4.6

140G-G3C4-C30

The 140G-G3C4-C30 is classified as a molded case circuit breaker that operates with a 125 amp capacity. This breaker is designed with a G frame and uses four poles for versatile applications. It maint

Call
5.0
Showing 201-210 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.