The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-G6C4-C80

This four-pole circuit breaker has fixed thermal and fixed magnetic protection. It operates within a current range of 80 A, along with thermal and magnetic trip settings of 80 A and 800 A, respectivel

Call
4.9

140G-G3C4-C25

The 140G-G3C4-C25 is a molded case circuit breaker with a G frame, rated for 125 Amps. It has a fixed thermal and fixed magnetic protection type, functioning efficiently with a 25 Amp current range. T

Available
4.9

140G-G3C4-C35

The model 140G-G3C4-C35 is a molded case circuit breaker employed as part of the G frame series. It supports a maximum current rating of 125 Amps and provides an interrupting capacity of 35 kA. This c

Call
4.9

140G-J3C3-C50

This circuit breaker has a current rating of 50 Amps, a maximum current of 250 Amps, and a rated insulation voltage of 1000 Volts. It also withstands impulse voltages reaching 8 kV. It guarantees effi

Available
4.9

140G-N6H3-E12-Z1

Rated for a current range of up to 1200 A, the 140G-N6H3-E12-Z1 features an N frame and incorporates electronic LSI protection. Its insulation voltage is rated at 1000 volts, while the impulse withsta

Call
4.7

140G-G3C4-C60

The 140G-G3C4-C60 is a molded case circuit breaker designed for reliable performance in various electrical systems. With a frame type designated as G, it operates at a maximum current of 125 Amps. Thi

Call
4.7

140G-G3C4-D10

This circuit breaker operates with four poles and has a fixed thermal and magnetic trip system. It supports a current range of 100 amps and is built to handle an insulation voltage rating of 800 volts

Call
4.9

140G-J6C3-C30

Designed for comprehensive protection, this molded case circuit breaker operates with a fixed thermal and magnetic trip setup. The unit can handle up to 30 A within its current range. It effectively m

Call
4.9

140G-G2C4-D12

The 140G-G2C4-D12, part of the Allen-Bradley 140G MCB series, is engineered as a molded case circuit breaker in a G frame size. With a maximum current rating of 125 Amps, it features a fixed thermal t

Call
4.6

140G-G6C3-C16

This molded case circuit breaker has three poles and accommodates a current range of 16 amps. It offers robust protection with a thermal trip setting at 16 amps and a magnetic trip threshold of 500 am

Call
4.4
Showing 211-220 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.