Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-JTF3-D15 from the 140G MCB series.
    Allen Bradley

    140G-JTF3-D15

    The 140G-JTF3-D15 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

    Available
    Call
  • 140G-H0C3-C40 from the 140G MCB series.
    Allen Bradley

    140G-H0C3-C40

    The 140G-H0C3-C40 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-J6H3-D10 from the 140G MCB series.
    Allen Bradley

    140G-J6H3-D10

    Operating at a maximum current range of 100 A, the 140G-J6H3-D10 features a rated insulation voltage of 1000 V. The rated impulse withstand voltage stands at 8 kV, ensuring reliability during voltage

    From $2,679
    In Stock Ships Today
  • 140G-JTI3-D25 from the 140G MCB series.
    Allen Bradley

    140G-JTI3-D25

    This J-frame breaker offers an interrupting rating supported by its trip unit, ensuring effective operation in various electrical environments. It is rated for insulation voltages of up to 1000 volts

    Available
    Call
  • 140G-H2H4-C60 from the 140G MCB series.
    Allen Bradley

    140G-H2H4-C60

    Categorized as a four-pole molded case circuit breaker, the 140G-H2H4-C60 is equipped with an electronic LSI protection mechanism. It accommodates a current range of 60 amps and is rated for insulatio

    From $973
    Available
  • 140G-H2C4-C70 from the 140G MCB series.
    Allen Bradley

    140G-H2C4-C70

    This circuit breaker supports a current range of up to 70 Amps and is rated for insulation voltage of 1000 V. It withstands impulse voltages up to 8 kV. Weighing 3.53 pounds, it provides robust mechan

    Available
    Call
  • 140G-G6C3-C32 from the 140G MCB series.
    Allen Bradley

    140G-G6C3-C32

    Operating within a current limit of 32 A, this circuit breaker features a G frame design. It incorporates fixed thermal and magnetic protection mechanisms to ensure safety. Rated for insulation up to

    Available
    Call
  • 140G-I3C3-D17 from the 140G MCB series.
    Allen Bradley

    140G-I3C3-D17

    This circuit breaker features a fixed thermal and magnetic protection type. It operates within a current range of 170 Amps, with a thermal trip point at 170 A and magnetic trip at 1700 A. It offers a

    Available
    Call
  • 140G-K6H3-D30 from the 140G MCB series.
    Allen Bradley

    140G-K6H3-D30

    This circuit breaker device operates with 300 A of rated current and is designed with electronic LSI protection. It has a frame size of K and can manage insulation voltages of up to 1000V. Additionall

    From $8,372
    Available
  • 140G-J6F3-D10 from the 140G MCB series.
    Allen Bradley

    140G-J6F3-D10

    The 140G-J6F3-D10 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

    Available
    Call
Showing 211-220 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.