140G-G3C3-C35
The 140G-G3C3-C35 circuit breaker is designed to handle a current range of 35 amps, ensuring effective operation in various applications. It has an interrupting capacity rated at 35 kA, allowing it to
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
The 140G-G3C3-C35 circuit breaker is designed to handle a current range of 35 amps, ensuring effective operation in various applications. It has an interrupting capacity rated at 35 kA, allowing it to
The 140G-H0C3-C60 features fixed thermal and fixed magnetic protection, allowing it to operate within a consistent current range of up to 60 Amps. Rated for insulation at 1000 volts and capable of wit
This breaker provides adjustable thermal and magnetic protection, accommodating a current range of 150 A. It supports rated insulation up to 1000 volts and impulse withstand voltage up to 8 kV. Weighi
With four poles, the 140G-H6C4-C40 model can handle currents up to 40 amps. Its protection capabilities come from fixed thermal and magnetic mechanisms. Additionally, the rated insulation voltage for
The 140G-G2C4-C80 is a molded case circuit breaker featuring a G frame designed by Rockwell Automation under the Allen Bradley brand. It provides fixed thermal and magnetic protection and operates at
The 140G-G3C3-D11 molded case circuit breaker is characterized by its G-frame design and is capable of handling an electrical load of up to 125 amps. With an interrupting rating of 35 kilohertz, it pr
This molded case circuit breaker operates with a current range of 20 Amps. It is built on an H frame with an insulation voltage rating of 1000 V and withstands impulse voltages up to 8 kV. The unit ha
This molded case circuit breaker operates within a current range of 120 A and includes a trip unit for interrupting rating. It supports rated insulation voltages of up to 1000 V while withstanding imp
This circuit breaker features adjustable thermal and magnetic protection options, making it versatile for various electrical system applications. It operates efficiently at 300 A of rated current and
Rated for a current range of up to 1200 A, the 140G-N6H3-E12-Z1 features an N frame and incorporates electronic LSI protection. Its insulation voltage is rated at 1000 volts, while the impulse withsta
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.