140G-N6I3-E12
This breaker features an N frame size and operates at a rated insulation voltage of 1000 volts. It can endure impulse voltages rated at 8 kV, making it suitable for varied applications. The unit weigh
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This breaker features an N frame size and operates at a rated insulation voltage of 1000 volts. It can endure impulse voltages rated at 8 kV, making it suitable for varied applications. The unit weigh
The 140G-G2C4-C60 is a molded case circuit breaker featuring a G Frame. It operates at 125 amps and is designed with four poles. Its fixed thermal and magnetic protection types ensure reliable circuit
The molded case circuit breaker, 140G-H0C4-C25, operates with a fixed thermal and magnetic protection mechanism. It includes four poles and supports a current range of 25 Amps. With a rated insulation
This circuit breaker features four poles and operates within a current range of 80 amps. It utilizes adjustable thermal and magnetic protection types for customizable safety settings. Rated insulation
This molded case circuit breaker operates with a frame size of H and supports a current range of 60 A. It employs electronic LSI protection to enhance safety and operational reliability. The rated ins
This molded case circuit breaker operates on a 1000 V rated insulation voltage and can withstand impulse voltages up to 8 kV. The protection method utilized is electronic LSIG, with four poles availab
This molded case circuit breaker utilizes a frame type H and is designed with four poles. It supports a current range of 40 A and operates safely with a rated insulation voltage of 1000 V. Additionall
With a current range of 70 A, the 140G-H15C4-C70 operates with four poles for effective circuit management. The device supports insulation ratings of 1000 volts and can withstand impulse voltages up t
This circuit breaker operates with a four-pole design and features electronic LSIG protection. The maximum interrupting capacity is rated at 25 kA, suitable for high-fault scenarios. The device can ma
This circuit breaker includes four poles and operates effectively within a current range of 35 A. Its rated insulation voltage is 1000 V, while it can withstand impulse voltages up to 8 kV. Weighing 3
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.