140G-H0F4-D12
This four-pole molded case circuit breaker operates with adjustable thermal and magnetic protection mechanisms. It supports a current range of up to 120 amps, while its rated insulation voltage is 100
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This four-pole molded case circuit breaker operates with adjustable thermal and magnetic protection mechanisms. It supports a current range of up to 120 amps, while its rated insulation voltage is 100
This circuit breaker features a four-pole design and is rated for 125 Amps, supporting a current range of up to 160 Amps. It has a rated insulation voltage of 1000 V and a rated impulse withstand volt
This breaker is designed with a 4-pole configuration and supports a current range of 50 A. Its fixed thermal and fixed magnetic protection types ensure reliability. The unit features a rated insulatio
This molded case circuit breaker features a four-pole configuration and supports a current range of 25 amps. It achieves a rated insulation voltage of 1000 volts while maintaining an impulse withstand
Designed for robustness, this model features a HC frame and is rated for insulation voltage up to 1000V. It has a rated impulse withstand voltage of 8 kV and is structured to support a high number of
This circuit breaker operates with a rated insulation voltage of 800 volts and can withstand impulses of up to 8 kV. It supports a current range of 80 A and has thermal and magnetic trip ratings of 80
This molded case circuit breaker is equipped with adjustable thermal and magnetic protection features. Operating within a current range up to 220 A, it has a rated insulation voltage of 1000V and with
This molded-case circuit breaker features electronic LSIG and MM protection and boasts a rated insulation voltage of 1000 volts. It can handle impulse withstand voltages of up to 8 kV. The device weig
This circuit breaker, featuring a K frame, functions effectively within a current range of up to 400 A. It is rated for up to 1000 volts of insulation voltage and withstands impulse voltages of up to
This device is built with a frame size of M and has four poles. It is designed to handle a current range of 630 Amps. Its rated insulation voltage is 1000 Volts, and it withstands impulse voltages up
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.