The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-H15F4-C90

This model offers an interrupting rating of 150 kA, ensuring effective fault protection. It provides both adjustable thermal and magnetic protection types. The breaker is classified for a current rang

Call
4.7

140G-J2F4-D17

This circuit breaker model features a robust frame designated as a type J frame and has a four-pole configuration. It supports a current rating of 170 A, up to 250 A of maximum current, and an interru

Call
4.7

140G-J3C3-C60

This circuit breaker has a J frame design. It supports a rated current of 60 A and has a 35 kA interrupting capacity. Its rated insulation voltage is 1000 V, and it can withstand impulse voltages of u

In Stock Ships Today
4.6

140G-JC0F3-D11

This circuit breaker operates within a current range of up to 110 A and features adjustable thermal and magnetic protection types. Rated for 1000 volts, it is equipped to withstand impulse voltages of

Call
4.7

140G-K15K3-D40

This molded-case circuit breaker features electronic LSIG and MM protection and boasts a rated insulation voltage of 1000 volts. It can handle impulse withstand voltages of up to 8 kV. The device weig

Call
4.9

140G-M6K3-D80

This circuit breaker is constructed with a frame classified as M and is capable of managing a current of 800 A. Rated for insulation of 1000 volts, it also withstands impulse voltages of up to 8 kV. T

Available
4.9

140G-N5K3-E12

The 140G-N5K3-E12 is a high-performance molded case circuit breaker suitable for industrial applications. This model accommodates a maximum current of 1200 amperes and is designed with an interrupting

Available
4.9

140G-H0F4-D12

This four-pole molded case circuit breaker operates with adjustable thermal and magnetic protection mechanisms. It supports a current range of up to 120 amps, while its rated insulation voltage is 100

Call
4.7

140G-H0I4-C60

This circuit breaker features a four-pole design and operates efficiently within a current range of 60 amps. It maintains a rated insulation voltage of 1000 V, alongside a rated impulse withstand volt

Call
4.7

140G-H15C3-C50

This circuit breaker features an interrupting capacity of 150 kA and supports a current range of 50 amps. It has a fixed thermal and magnetic protection mechanism. With a rated insulation voltage of 1

Call
5.0
Showing 381-390 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.