140G-H6F4-D16
This circuit breaker is defined by 4 poles and accommodates a maximum current range of 160 A. It possesses adjustable protection for both thermal and magnetic trips. Rated for an insulation voltage of
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker is defined by 4 poles and accommodates a maximum current range of 160 A. It possesses adjustable protection for both thermal and magnetic trips. Rated for an insulation voltage of
This circuit breaker is classified under the HC frame type and supports a current range of 32 A. It holds a rated insulation voltage of 1000 volts and sustains impulse withstand voltages of 8 kV. Its
This circuit breaker operates within a current range of 120 A. It utilizes advanced Electronic LSI protection, ensuring effective response to electrical faults. With a rated insulation voltage of 1000
This 4-pole circuit breaker has a current range of 60 A. It offers a rated insulation voltage of 1000 V and can withstand impulse voltages of up to 8 kV. The device weighs approximately 3.53 pounds, w
This circuit breaker comes with a type J frame, four poles, a current rating of 50 A, and a maximum current of 250 A. It is engineered for a rated insulation voltage of 1000 V and can withstand impuls
This breaker model features a four-pole configuration and operates with a rated insulation voltage of 1000 volts. It withstands impulse voltages of up to 8 kV. The 140G-J2X4 breaker has a mechanical l
This circuit breaker is configured with a J-frame and supports a current range of 250 Amps. It is rated for an insulation voltage of 1000 volts and can withstand impulse voltages of 8 kV. The unit wei
The 140G-JTI4-C40 breaker model has four poles and supports a rated current of 40 A. It has an insulation voltage rating of 1000V and is designed to handle impulse withstand voltages up to 8 kV. The d
This circuit breaker supports a current range of 400 Amps and includes four poles. It has a rated insulation voltage of 1000 volts and withstands impulse voltages of up to 8 kV. Weighing 9.15 pounds,
The 140G-H0C4-C70 circuit breaker features four poles and operates within a current range of 70 Amps. It has a high interrupting rating of 100 kA, ensuring it can handle severe fault conditions. It is
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.