The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-H6I3-C25

This model supports a current range of 25 A and utilizes electronic LSIG protection. It operates under rated insulation voltages of 1000 V and withstands impulse voltages of up to 8 kV. Weighing 2.65

Call
4.7

140G-J0H4-C60

The 140G-J0H4-C60 circuit breaker is equipped with four poles and electronic LSI protection and it can manage a rated current of up to 60 amps. It has a rated insulation voltage of 1000 volts and can

Call
5.0

140G-J6H4-C40

This circuit breaker is configured with four poles and supports a thermal current range of 40 Amps. It is rated for insulation at 1000V, making it suitable for high-voltage applications. The device ca

Call
4.9

140G-J6I3-C60

This circuit breaker operates within a current range of 60 Amps. It is rated for an insulation voltage of 1000 Volts, providing compatibility for high-voltage applications. Additionally, it withstands

Call
5.0

140G-JTF3-C90

This circuit breaker includes a rated insulation voltage of 1000 volts and can withstand impulse voltages up to 8 kV. Its weight is approximately 5.51 pounds. The 140G-JTF3-C90 has a mechanical lifesp

Call
4.9

140G-M6K3-D63

This circuit breaker operates efficiently within a current range of 630 A and features an interrupting rating of 65 kA. It is housed in an M-frame structure and exhibits strong durability characterist

Call
4.9

140G-J0F3-D20

This molded case circuit breaker features an adjustable thermal and magnetic protection type. It operates within a current range of up to 200 A and has a rated insulation voltage of 1000 volts. The br

Call
4.6

140G-H0C3-C35

This device belongs to the Allen-Bradley 140G series, showcasing its H-frame design. It features a fixed thermal and magnetic protection mechanism, ensuring safeguarding against various fault conditio

Call
4.5

140G-H0C4-C35

Designed as part of the 140G series, the 140G-H0C4-C35 model features a frame size categorized under H. This circuit breaker includes four poles and accommodates a current range of up to 35 A. It offe

Call
5.0

140G-H0C4-C50

This model features a robust H frame design and is equipped with four poles. The unit operates within a current range of 50 Amps and is designed for insulation voltages rated at 1000 V. It also has an

Call
5.0
Showing 441-450 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.