Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H0C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-H0C4-C40

    The 140G-H0C4-C40 serves as a four-pole, molded case circuit breaker with a specified current range of 40 Amps. It provides both fixed thermal and fixed magnetic protection types, with a rated insulat

    Available
    Call
  • 140G-H2C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-H2C4-C25

    This particular model is designed with a four-pole configuration, catering to a current range of 25 A. It supports high voltages, with a rated insulation voltage of 1000 V and imparts durability throu

    Available
    Call
  • 140G-H6H3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H6H3-D16

    Rated for 160 Amps in current range, this device employs electronic LSI protection. It can withstand insulation voltages up to 1000 volts and impulse withstand voltages of 8 kV. The unit has a mechani

    Available
    Call
  • 140G-HC6C3-C32 from the 140G MCB series.
    Allen Bradley

    140G-HC6C3-C32

    This model operates at a specified current range of 32 A and is built within an HC frame. It boasts an interrupting capacity of 65 kA. The perfect solution for high-performance environments, its insul

    Available
    Call
  • 140G-J0H4-C60 from the 140G MCB series.
    Allen Bradley

    140G-J0H4-C60

    The 140G-J0H4-C60 circuit breaker is equipped with four poles and electronic LSI protection and it can manage a rated current of up to 60 amps. It has a rated insulation voltage of 1000 volts and can

    Available
    Call
  • 140G-J2F4-D17 from the 140G MCB series.
    Allen Bradley

    140G-J2F4-D17

    This circuit breaker model features a robust frame designated as a type J frame and has a four-pole configuration. It supports a current rating of 170 A, up to 250 A of maximum current, and an interru

    Available
    Call
  • 140G-K0F4-D40 from the 140G MCB series.
    Allen Bradley

    140G-K0F4-D40

    This four-pole circuit breaker features adjustable thermal and magnetic protection technology. It operates with a current capacity of 400 A, has a rated insulation voltage of 1000 volts, and withstand

    Available
    Call
  • 140G-K0K4-D30 from the 140G MCB series.
    Allen Bradley

    140G-K0K4-D30

    With a rated insulation voltage of 1000V, this breaker offers reliable performance under various electrical conditions. It also withstands impulse voltages up to 8 kV. Weighing 9.15 pounds, the device

    Available
    Call
  • 140G-K6K3-D40 from the 140G MCB series.
    Allen Bradley

    140G-K6K3-D40

    This circuit breaker is designed with a K frame and supports current handling at up to 400 A. The insulation voltage rating reaches 1000 Volts, and it withstands impulse voltages up to 8 kV. It weighs

    Available
    Call
  • 140G-KC6H3-D40 from the 140G MCB series.
    Allen Bradley

    140G-KC6H3-D40

    This circuit breaker operates with a KC frame and has a robust current rating of 400 A. It can withstand rated insulation voltages up to 1000 volts and impulse withstand voltages of 8 kV. Weighing 7.1

    Available
    Call
Showing 451-460 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.