140G-HC0F3-D12
Designed for current ranges of up to 120 A, this circuit breaker features adjustable thermal and magnetic protection types. It has a rated insulation voltage of 1000V and withstands impulse voltages o
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
Designed for current ranges of up to 120 A, this circuit breaker features adjustable thermal and magnetic protection types. It has a rated insulation voltage of 1000V and withstands impulse voltages o
This molded case circuit breaker features a current range accommodating up to 100 Amps, with a thermal trip rated at 100 Amps and a magnetic trip capability of 1000 Amps. It is designed for operationa
This four-pole circuit breaker operates within an adjustable thermal and magnetic protection mechanism, covering a current range up to 170 A. It has a rated insulation voltage of 1000 V and an impulse
Designed with four poles, the 140G-J6H4-D15 supports a current range of 15 Amps. It has a rated insulation voltage of 1000 volts and is capable of handling impulse withstand voltages up to 8 kV. The u
Designed for applications requiring high levels of power and protection, the 140G-K0I3-D40 supports a current rating of up to 400 A. It also supports insulation voltage ratings of 1000 V and withstand
This circuit breaker is designed with four poles and accommodates a rated current of 400 A. It possesses a rated insulation voltage of 1000 volts and has a reliable impulse withstand voltage of up to
This circuit breaker operates within a range of 1200 A and features an N frame. It has a rated insulation voltage of 1000 volts and can endure impulse voltages up to 8 kV. Weighing 21.39 pounds, it su
This model features a 4-pole configuration and operates within a current range of 150 A. It integrates fixed thermal and magnetic trip functions, with a thermal trip setting at 150 A and a magnetic tr
This auxiliary contacts unit features a single auxiliary contact and one alarm contact, with a rated current capacity of 6 amps. It operates at a wire gauge size of 18 AWG and is compatible with multi
This circuit breaker features an interrupting capacity of 150 kA and supports a current range of 50 amps. It has a fixed thermal and magnetic protection mechanism. With a rated insulation voltage of 1
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.