140G-KTI4-D40
This circuit breaker operates with an interrupting rating controlled via a trip unit and supports a current range of 400 A. Its rated insulation voltage stands at 1000 volts, and it can withstand impu
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker operates with an interrupting rating controlled via a trip unit and supports a current range of 400 A. Its rated insulation voltage stands at 1000 volts, and it can withstand impu
Configured with four poles, the 140G-K3H4-D30 supports a rated current of 300 A and operates effectively at insulation voltages of 1000 volts. The breaker can withstand impulse voltages up to 8 kV. It
This circuit breaker operates within a frame classified as H and has an adjustable thermal and magnetic protection feature. It supports a current range of up to 90 amps and is rated for insulation vol
This molded case circuit breaker provides an interrupting capability of 100 kA. It operates effectively with a rated insulation voltage of 1000 volts and can withstand impulse voltages up to 8 kV. The
Rated for 125 amps, the 140G-H0I3-C25 provides electronic LSIG protection within a current range of 25 A. The unit is enclosed in an H frame and meets insulation requirements up to 1000 V with an impu
This molded case circuit breaker, model 140G-H15I3-D10, is built with an H-frame structure. It provides excellent protection with a maximum current range of 100 A. The insulation voltage rating is 100
This circuit breaker, rated for 90 Amps, ensures effective overcurrent protection with an interrupting capacity of 25 kA. It supports a rated insulation voltage of 1000 volts and an impulse withstand
This model features a frame size denoted as H and operates within a current range of 25 Amps. It supports a rated insulation voltage of 1000 volts and can tolerate impulse voltages of 8 kV. Weighing a
Operating within a J frame, this circuit breaker supports a current range of 110 A. It features adjustable thermal and magnetic protection capabilities. The unit's rated insulation voltage is 1000 V,
This circuit breaker operates within a current range of 60 Amps. It is rated for an insulation voltage of 1000 Volts, providing compatibility for high-voltage applications. Additionally, it withstands
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.