140G-J2C4-C32
This four-pole circuit breaker operates with a current rating of 32 Amps and a maximum current of 250 Amps. It incorporates fixed thermal and fixed magnetic protection mechanisms. The rated insulation
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This four-pole circuit breaker operates with a current rating of 32 Amps and a maximum current of 250 Amps. It incorporates fixed thermal and fixed magnetic protection mechanisms. The rated insulation
This breaker is configured within a current range of 32 Amps and features fixed thermal and magnetic protection types. It is rated for an insulation voltage of 1000 volts and withstands impulse voltag
This molded case circuit breaker operates within a current range of 170 Amps and utilizes adjustable thermal and magnetic protection mechanisms. It can handle rated insulation voltages up to 1000 Volt
This circuit breaker is built with four poles and supports a current range of 400 A. It has a rated insulation voltage of 1000 volts and can endure impulse withstand voltages up to 8 kV. The 140G-K3H4
This circuit breaker operates efficiently within a current range of 630 A and features an interrupting rating of 65 kA. It is housed in an M-frame structure and exhibits strong durability characterist
This circuit breaker operates effectively in a temperature range from 0 to 40 °C. It supports a maximum operating humidity of 80% and maintains the same level for storage conditions. Designed with an
This model offers four poles and operates within a current range of 32 Amps. Its fixed thermal and fixed magnetic protection ensure the safety and integrity of the electrical system. Rated for 1000 Vo
The 140G-H15C3-C70 circuit breaker is characterized by its fixed thermal and fixed magnetic protection types. It functions within a current range of up to 70 A. The insulation voltage rating is noted
This circuit breaker is a part of the H frame series and utilizes a fixed thermal and fixed magnetic protection type. It supports a current range of 70 amps and is configured with four poles. The rate
This breaker offers adjustable thermal and magnetic protection to adapt to different application needs. Designed for four-pole configuration, it operates within a current range of 80 amps. The insulat
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.