140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H6I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H6I3-C60

    This circuit breaker is built within an H frame and designed to handle a current range of 60 A. It maintains a rated insulation voltage of up to 1000 V and withstands impulse voltages of 8 kV. Weighin

    Available
    Call
  • 140G-HC6C3-C15 from the 140G MCB series.
    Allen Bradley

    140G-HC6C3-C15

    This circuit breaker is designed for a current range of 15 Amps. It features fixed thermal and fixed magnetic protection types. The rated insulation voltage stands at 1000 volts, with an impulse withs

    Available
    Call
  • 140G-HC6C3-C35 from the 140G MCB series.
    Allen Bradley

    140G-HC6C3-C35

    This molded case circuit breaker operates within a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. The current range for this device is set at 35 Amps. Measuri

    Available
    Call
  • 140G-HC6I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-HC6I3-C60

    This molded case circuit breaker is capable of handling a current range of 60 A. It is rated for insulation up to 1000 volts and withstands impulse levels of 8 kV. The unit weighs 2.65 pounds and has

    Available
    Call
  • 140G-HTH3-D10 from the 140G MCB series.
    Allen Bradley

    140G-HTH3-D10

    Part of the HC frame series, the 140G-HTH3-D10 features electronic LSI protection and a current range capped at 100 A. It can withstand impulse voltages of 8 kV and weighs 2.65 pounds. The mechanical

    Available
    Call
  • 140G-J0C4-C32 from the 140G MCB series.
    Allen Bradley

    140G-J0C4-C32

    This circuit breaker operates with a fixed thermal and fixed magnetic protection type and features four poles. It supports a current range of 32 amps and is built to manage insulation voltages of 1000

    Available
    Call
  • 140G-J0H4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J0H4-D15

    Configured with four poles, the 140G-J0H4-D15 circuit breaker features electronic LSI protection and supports a current rating of up to 150 amps. The breaker's insulation voltage is rated at 1000 volt

    Available
    Call
  • 140G-J2F3-C80 from the 140G MCB series.
    Allen Bradley

    140G-J2F3-C80

    This circuit breaker operates with adjustable thermal and and adjustable magnetic protection technology. It supports a current rating of 80 Amps and has a rated insulation voltage of 1000 V. Additiona

    From $1,485
    Available
  • 140G-JC0F3-D25 from the 140G MCB series.
    Allen Bradley

    140G-JC0F3-D25

    The 140G-JC0F3-D25 circuit breaker supports a current capacity of 250 A with an insulation voltage rated at 1000V. It can withstand impulse voltages of up to 8 kV. Weighing 5.51 pounds, the device ope

    Available
    Call
  • 140G-JC0I3-D10 from the 140G MCB series.
    Allen Bradley

    140G-JC0I3-D10

    This circuit breaker belongs to the JC frame design. It maintains an impressive rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. Weighing in at 5.51 pounds, it

    Available
    Call
Showing 551-560 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.