140G-KC0F3-D30
This product features a KC frame and operates effectively at 300 A of rated current. The circuit breaker is rated for an insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. It wei
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This product features a KC frame and operates effectively at 300 A of rated current. The circuit breaker is rated for an insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. It wei
This molded case circuit breaker utilizes a KC frame design and operates efficiently with a rated current of 300 A. It can handle insulation voltage levels reaching up to 1000V and withstand impulse v
With four poles, the 140G-M0K4-D60 is capable of managing a current range of 600 A. It also offers electronic LSIG protection, making it suitable for various industrial applications. The rated insulat
This molded case circuit breaker utilizes a frame size designated as M and accommodates a current range of up to 630 Amps. It includes four poles and adjustable thermal and magnetic protection setting
This model is built under the N-frame designation, supporting electronic LSIG protection. It features a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. The wei
This molded case circuit breaker is designed for current applications up to 80 Amps. It has an insulation voltage rating of 1000 volts and can withstand impulse voltages of 8 kV. The weight of the 40G
Featuring a flexible cable size of 6 ft, the 140G-H-FMX06 circuit breaker has an interrupting capacity of 10 kA and insulation rated up to 1000 V. The device is housed in an enclosure rated NEMA Type
This circuit breaker features an H-frame designation and includes four poles. It employs electronic LSI protection technology, enhancing reliability during operation. With a 100 Amp current range and
Fitting into the H frame category, the 140G-H2C4-C32 operates with a current range of up to 32 A. It features four poles and fixed thermal and magnetic protection methods. This unit maintains insulati
Designed with an H frame, the 140G-H2F4-D10 accommodates up to four poles. It handles current within a range of 100 A and has insulation voltage ratings reaching 1000 V. Its rated impulse withstand vo
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.