140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-HC0C3-C40 from the 140G MCB series.
    Allen Bradley

    140G-HC0C3-C40

    This model is built with an HC frame and specifies a current range of 40 A. The insulation voltage of the circuit breaker is rated at 1000V, while it is capable of withstanding impulse voltages of up

    Available
    Call
  • 140G-HC0H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-HC0H3-C60

    Designed with an HC frame, this breaker includes protection through its Electronic LSI system. It safely handles currents up to 60 Amps and features a rated insulation voltage of 1000 volts. The break

    Available
    Call
  • 140G-HTH3-C60 from the 140G MCB series.
    Allen Bradley

    140G-HTH3-C60

    Part number 140G-HTH3-C60 features a current range of 60 Amps and operates with a rated insulation voltage of 1000 volts. This unit withstands impulse voltages of up to 8 kV. Weighing 2.65 pounds, it

    Available
    Call
  • 140G-I2C4-C90 from the 140G MCB series.
    Allen Bradley

    140G-I2C4-C90

    With a four-pole configuration, this circuit breaker has a thermal trip setting of 90 Amps and a magnetic trip rating of 900 Amps. It supports a current range of up to 90 A, with an insulation voltage

    Available
    Call
  • 140G-I3C4-D12 from the 140G MCB series.
    Allen Bradley

    140G-I3C4-D12

    Operating with a current range of 120 A, this circuit breaker supports four poles. Its rated insulation voltage is 800V and it can withstand impulse voltages up to 8 kV. Weighing 5.73 pounds, the mode

    Available
    Call
  • 140G-J0F3-C80 from the 140G MCB series.
    Allen Bradley

    140G-J0F3-C80

    With a frame size designated as J, this circuit breaker operates within an adjustable current range of 80 Amps. It supports a rated insulation voltage of 1000 volts and can endure impulse withstand vo

    Available
    Call
  • 140G-J0F4-D17 from the 140G MCB series.
    Allen Bradley

    140G-J0F4-D17

    Configured for a current range of 170 A, the 140G-J0F4-D17 circuit breaker operates at a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. Weighing 7.72 pounds, this circu

    Available
    Call
  • 140G-J0H3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J0H3-C40

    This circuit breaker utilizes electronic LSI technology for advanced protection and operates with a rated current of 40 A. It withstands rated insulation voltages up to 1000V, and its maximum impulse

    Available
    Call
  • 140G-J2I3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J2I3-C40

    This circuit breaker has a J-frame size. It operates with a rated current of 40 Amps and a maximum current of 250 Amps. It incorporates an electronic LSIG protection mechanism. It is rated to handle i

    Available
    Call
  • 140G-J3C3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J3C3-C40

    The 140G-J3C3-C40 is a molded case circuit breaker with a maximum current rating of 250 Amps and an interrupting rating of 35 kA. Its rated current is 40 Amps and it operates at an insulation voltage

    Available
    Call
Showing 791-800 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.