Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H3F3-C90 from the 140G MCB series.
    Allen Bradley

    140G-H3F3-C90

    This molded case circuit breaker features four poles and has a current range set at 90 amps. It provides a rated insulation voltage capability of up to 1000 volts and supports an impulse withstand vol

    Available
    Call
  • 140G-H6I3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H6I3-D16

    Designed for performance, the 140G-H6I3-D16 operates with an adjustable current range of 160 Amps. It has a rated insulation voltage of 1000 V and can withstand impulse voltages up to 8 kV. This unit

    Available
    Call
  • 140G-HC0F3-C90 from the 140G MCB series.
    Allen Bradley

    140G-HC0F3-C90

    This device offers adjustable thermal and magnetic protection and operates within a current range of 90 A. It is rated for insulation voltage and impulse withstand voltage of 1000 V and 8 kV, respecti

    Available
    Call
  • 140G-HC6C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-HC6C3-C70

    This circuit breaker is designed with a current range of up to 70 A and features fixed thermal and magnetic protection mechanisms. It operates effectively at a rated insulation voltage of 1000 volts a

    Available
    Call
  • 140G-HTC4-C63 from the 140G MCB series.
    Allen Bradley

    140G-HTC4-C63

    This circuit breaker is rated for a current of 63 A and offers fixed thermal and magnetic protection features. It maintains a rated insulation voltage of 1000 V and withstands impulse voltages up to 8

    Available
    Call
  • 140G-HTI3-D10 from the 140G MCB series.
    Allen Bradley

    140G-HTI3-D10

    This model from the 140G MCB series operates under a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. It weighs 2.65 pounds and provides a mechanical life ratin

    Available
    Call
  • 140G-I3C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-I3C3-C63

    This circuit breaker features an I frame and utilizes fixed thermal and fixed magnetic protection types. It operates within a current range of 63 A, with a thermal trip threshold of 63 A and a magneti

    Available
    Call
  • 140G-J0C3-C32 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C32

    This model operates with a frame designation of J and provides fixed thermal and magnetic protection. It can handle a current range of 32 amps, with a rated insulation voltage of 1000 volts and an imp

    Available
    Call
  • 140G-J0C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C60

    Rated at 250 amps with a current range of 60 A, this molded case circuit breaker employs fixed thermal and magnetic protection methods. It supports a rated insulation voltage of 1000V and withstands i

    Available
    Call
  • 140G-J2C3-C30 from the 140G MCB series.
    Allen Bradley

    140G-J2C3-C30

    This molded case circuit breaker operates with fixed thermal and fixed magnetic protection types. It supports a rated current of 30 A and a maximum current rating of 250 A. It is rated for an insulati

    Available
    Call
Showing 821-830 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.