Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-K6K3-D30 from the 140G MCB series.
    Allen Bradley

    140G-K6K3-D30

    This circuit breaker operates with 300 A of rated current and has an impressive rated insulation voltage of 1000 V. Additionally, it can withstand impulse voltages of 8 kV, enhancing its durability in

    Available
    Call
  • 140G-M5I4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M5I4-D63

    This breaker features an M frame and offers four poles. It has a current range up to 630 A, operating with a rated insulation voltage of 1000 volts. The unit can withstand impulse voltages of up to 8

    Available
    Call
  • 140G-M6H4-D80 from the 140G MCB series.
    Allen Bradley

    140G-M6H4-D80

    This 4-pole circuit breaker falls under the Molded Case Breaker category. It operates within a current range of 800 A and boasts an insulation voltage rating of 1000 volts. Additionally, it can withst

    Available
    Call
  • 140G-M6K4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M6K4-D63

    This circuit breaker manages a current range of 630 A and is engineered for a rated insulation voltage of 1000 volts. It is capable of withstanding impulse voltages of up to 8 kV. With a weight of 33.

    Available
    Call
  • 140G-NS0I3-E12 from the 140G MCB series.
    Allen Bradley

    140G-NS0I3-E12

    Operating within a current range of 1200 Amps, this NS frame breaker features electronic LSIG protection and is built for high-performance applications. It has a rated insulation voltage of 1000 volts

    Available
    Call
  • 140G-R12I4-E20 from the 140G MCB series.
    Allen Bradley

    140G-R12I4-E20

    This circuit breaker is rated for a current range of 2000 Amps and established with four poles. It has a rated insulation voltage of 1000 volts and can handle impulse withstand voltage up to 12 kV. We

    Available
    Call
  • 140G-J2I3-D15 from the 140G MCB series.
    Allen Bradley

    140G-J2I3-D15

    The 140G-J2I3-D15 features electronic LSIG protection and operates at a rated insulation voltage of 1000 volts. It can withstand impulse voltages up to 8 kV. This breaker weighs 5.51 pounds and is bui

    Available
    Call
  • 140G-I3C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-I3C3-C60

    This molded case circuit breaker is designed within an I frame, providing a versatile 225 amp rating. It features a maximum interrupting capacity of 35 kA. The 140G-I3C3-C60 also has a current range o

    Available
    Call
  • 140G-J0I3-D25 from the 140G MCB series.
    Allen Bradley

    140G-J0I3-D25

    The 140G-J0I3-D25 features a J frame and is suitable for circuits requiring a 250-Amp capacity. It has an insulation voltage rating of 1000 volts and can handle impulse withstand voltages of up to 8 k

    Available
    Call
  • 140G-H15H3-D12 from the 140G MCB series.
    Allen Bradley

    140G-H15H3-D12

    As a molded case circuit breaker, the 140G-H15H3-D12 falls within the H frame category. It supports a continuous current range of up to 120 amperes and operates with an insulation voltage rating of 10

    Available
    Call
Showing 811-820 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.