140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J2F4-C80 from the 140G MCB series.
    Allen Bradley

    140G-J2F4-C80

    This circuit breaker has a type J frame and is designed to handle an operational current rating of 80 amps. Its insulation voltage rating is 1000 volts, and it can withstand impulse voltages up to 8 k

    Available
    Call
  • 140G-J3C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-J3C3-C63

    This circuit breaker accommodates a rated current of 63 A and a maximum current of 250 A. It has an interrupting capacity of 35 kA. Its rated insulation voltage is 1000V, and it can endure impulse vol

    Available
    Call
  • 140G-J3F4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J3F4-D15

    This breaker is configured with four poles and supports an adjustable thermal and magnetic protection type. It operates within a current range of 150 A, ensuring flexibility for different application

    Available
    Call
  • 140G-J6C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-J6C4-C25

    This circuit breaker operates with a current range of 25 A and is equipped with four poles. Its rated insulation voltage is 1000 volts, allowing it to function safely in elevated voltage environments.

    Available
    Call
  • 140G-J6I4-D25 from the 140G MCB series.
    Allen Bradley

    140G-J6I4-D25

    This circuit breaker is composed of four poles and functions within a rated insulation voltage of 1000 volts. Its design can withstand impulse voltages reaching 8 kV. Weighing 7.72 pounds, it features

    Available
    Call
  • 140G-JC0C3-C25 from the 140G MCB series.
    Allen Bradley

    140G-JC0C3-C25

    This molded case circuit breaker utilizes a JC frame type and features fixed thermal and magnetic protections. It has a current range of 25 A and is rated for an insulation voltage of 1000 volts. The

    Available
    Call
  • 140G-JC0C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-JC0C3-C63

    This unit features a JC frame and operates within a current range of 63 A. It supports a rated insulation voltage of 1000 volts and withstands impulse voltages up to 8 kV. Weighing 5.51 pounds, it has

    Available
    Call
  • 140G-JC0H3-D15 from the 140G MCB series.
    Allen Bradley

    140G-JC0H3-D15

    This molded case circuit breaker operates with the JC frame and boasts a current handling capability up to 150 A. It is rated for an insulation voltage of 1000 volts and can withstand impulse voltages

    Available
    Call
  • 140G-JC6C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-JC6C3-C63

    This circuit breaker model provides a rated insulation voltage of 1000 volts. It is equipped with a 63 A current range and incorporates multiple features for stable operation. Weighing 5.51 pounds, it

    Available
    Call
  • 140G-JC6F3-D12 from the 140G MCB series.
    Allen Bradley

    140G-JC6F3-D12

    Designed with a frame size of JC, the 140G-JC6F3-D12 operates within a current range of 120 A. It has a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. Weighin

    Available
    Call
Showing 831-840 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.