140G-J6H4-D10
The 140G-J6H4-D10 circuit breaker features a J frame and operates with four poles. Capable of handling a current range of 100 A, it provides a rated insulation voltage of 1000 volts. This device withs
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
The 140G-J6H4-D10 circuit breaker features a J frame and operates with four poles. Capable of handling a current range of 100 A, it provides a rated insulation voltage of 1000 volts. This device withs
This breaker features adjustable thermal and magnetic protection with a JC frame configuration. It supports an insulation voltage of up to 1000 V and has an impulse withstand rating of 8 kV. The unit
Constructed with a JC frame, this breaker supports a current handling range of up to 40 Amps. It features an electronic LSI protection mechanism for efficient performance. The unit operates at a rated
This molded case circuit breaker operates on a JC frame and manages a current range of 60 Amps. Its rated insulation voltage is 1000V, while it withstands impulse voltages up to 8 kV. Weighing in at 5
This device operates in a current range of 40 Amps and is equipped with a JC frame. It features a rated insulation voltage of 1000 volts and can endure impulse withstand voltages of up to 8 kV. Weighi
Configured to handle a current range up to 90 Amps, the 140G-JTF4-C90 allows for precise control within industrial environments. It boasts an insulation voltage rating of 1000 volts and is capable of
This molded case circuit breaker supports a current range of 250 A and includes a rated insulation voltage of 1000 V. The device is capable of withstanding impulse voltages up to 8 kV. Weighing 7.72 p
This circuit breaker model, part of the Allen Bradley 140G series, features a JC frame and can handle up to 250 Amps. It has an interrupting rating that operates via a trip unit, ensuring overcurrent
This circuit breaker is designed with a frame classification of M and operates within a current range of 630 Amps. It is rated for an insulation voltage of 1000 Volts and can withstand impulse voltage
This circuit breaker features a maximum current capacity of 800 A and operates within a frame classification of M. It has an insulation voltage rating of 1000 V and can withstand impulse voltages up t
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.