Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-KC0H3-D30

This breaker model operates with a rated current of 300 Amps and offers a rated insulation voltage of 1000 volts. The impulse withstand voltage is rated at 8 kV. The breaker weighs 7.17 pounds and has

Call
4.8

140G-M0F3-D63

This circuit breaker is designed in an M-frame format and operates with a rated current of 630 A. It features a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. The unit

Call
5.0

140G-M0F4-D63

This circuit breaker uses an M frame and accommodates a rated current of 630 Amps. It features adjustable thermal and magnetic protection settings. With a maximum rated insulation voltage of 1000 volt

Call
4.8

140G-M0F4-D80

The 140G-M0F4-D80 features a four-pole configuration and adjustable thermal and magnetic protection technology. It maintains a rated insulation voltage of 1000 volts and withstands impulse voltages of

Call
5.0

140G-M0H3-D60

This molded case circuit breaker operates within a current range up to 600 A. It has a rated insulation voltage of 1000 Volts and is able to withstand impulse voltages of up to 8 kV. Weighing 26.68 po

Call
4.6

140G-M0H3-D80

The 140G-M0H3-D80 belongs to the M frame type and accommodates a maximum current of 800 A. It provides a rated insulation voltage of 1000 volts and withstands impulse voltage up to 8 kV. Weighing 26.6

Call
4.7

140G-M5K4-D60

This model includes four poles and operates within a current range of 600 A. It supports a rated insulation voltage of 1000 V. The device is designed to endure impulse withstand voltages up to 8 kV. W

Call
5.0

140G-M6K4-D63

This circuit breaker manages a current range of 630 A and is engineered for a rated insulation voltage of 1000 volts. It is capable of withstanding impulse voltages of up to 8 kV. With a weight of 33.

Call
4.7

140G-N0I4-E12

This molded case circuit breaker is designed with a frame type N and is capable of handling a current range of 1200 A. It supports a rated insulation voltage of 1000 Volts with impulse withstand capab

Call
4.7

140G-N6H4-E12

The 140G-N6H4-E12 circuit breaker, featuring a four-pole configuration, operates efficiently within a current range of 1200 A. With a rated insulation voltage of 1000V and impulse withstand voltage of

Call
4.9
Showing 971-980 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.