We offer extensive repairs for your Panelview 300 and Panelview 300 Micro. We keep many spare parts in stock so that we can repair your Panelview 300 as efficiently and effectively as possible. Our standard repair lead time is 3-5 days. However, we can often repair your unit much faster if necessary. We can repair most issues with your Panelview 300 and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your Panelview 300 parts.

Browse Panelview 300 Repairs

Browse our catalog of repairable Panelview 300 parts to get a quote.

2711-K3A5L1KX

Operating at 24V DC, this model includes a keypad and features an RS-232 communication port with DH-485 compatibility. It comes with a conformal coating for enhanced protection, and the enclosure meet

Call

2711-M3A18L1

This versatile interface terminal supports an input voltage range of 11 to 30 volts DC and operates with a power consumption of 2.5 watts. The device includes a DF1 port for communication and provides

In Stock Ships Today

2711-M3A18L1X

Designed for indoor applications, the PanelView Micro 300 offers a 3-inch monochrome display with a resolution of 128 x 64 pixels. It has a display area of 73 x 42 mm and supports an input voltage ran

In Stock Ships Today

2711-M3A19L1X

This operator terminal is equipped with a micro keypad and four function keys for user input. It offers an application memory capacity of 170 KB while having a total of 240 KB of nonvolatile storage f

In Stock Ships Today

2711-MT14

This operator interface unit supports a power supply range of 90-264 volts and operates efficiently in temperatures from 0 to 55 ⁰C. Its black housing has been designed to integrate with various syste

In Stock Ships Today

2711-MT20

With compliance to UL, cULus, and CE standards, this operator interface is designed for reliability in industrial settings. It allows for touch input and utilizes LED indicators for local signaling. T

Available
Showing 11-19 of 19 results

About Panelview 300

The compactly manufactured PanelView 300 and Panelview 300 Micro terminals from Allen-Bradley feature a 3-inch monochrome display. The display shows status updates and information in blue. The resolution of the monochrome display is 128 x 64 pixels. The terminals work with 24 Volts DC voltage. The display area of all the terminals in this series is 2.87 inches in width and 1.67 inches in height. The backlight used in these terminals has a life of 100,000 hours. For entering input data, a keypad with navigational, numerical, and functional keys is included. The PanelView 300 terminals record critical timestamp data by using replaceable batteries. The batteries power the real-time clock used in these terminals. Some of the terminals in this series support ATA memory cards and some don’t.

For connectivity, the PanelView 300 terminals use the RS-232 (DH-485), RS-232 (DF1), and DeviceNet networks. The network status is shown on the display terminal. The terminal can be controlled using the PanelView 32 software too. The software runs on a personal computer. The DC power consumption varies in different PanelView 300 terminals. Some terminals in the series have a DC power consumption rating of 10 Watts and some have a power consumption of 25 Watts. The operating temperature of these terminal ranges between 0 and 55 degrees Celsius. The PanelView 300 terminals come with different enhanced features including alarms, screen security, analog gauges, and support for Micrologix controllers. The terminals have multilingual support with English, French, Italian, German, and Spanish Text options. The terminals in this series use 240 KB of application memory. It also comes with NEMA Type 12, 13, 4X ratings. These terminals are ideal for customers who need cost-effective devices that save space.

Common Errors Codes that we may be able to repair for the Panelview 300 and Panelview 300 Micro (2711-K3 and 2711-M3):

  • Error 1 STATIC RAM test
  • Error 2 Terminal searching for a file to download.
  • Error 10 Erase boot flash area.
  • Error 11 Copy boot code
  • Error 12 Boot code copy successful
  • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
  • Error 30 Watchdog test
  • Error 31 Stuck key test
  • Error 32 Real time clock test
  • Error 33 LCD RAM failed
  • Error 50 Wrong memory card format