6702 results
Allen Bradley / PLCs / ControlLogix
This high-speed analog I/O module supports input voltage ranging from -10 to 10 volts, as well as 4 to 20 mA. With a total power consumption of 4.3 watts, it operates with an input current draw of 375 mA at 5.1 volts and 100 mA at 24 volts. The operating temperature range is suitable from 32°F to 14
Allen Bradley / PLCs / CompactLogix
Allen Bradley CompactLogix 5370 L1 Controller, Dual Ethernet withDLR enabled, 512Kilobyte capacity of memory, 8 I-O extension via 1734 PT. I-O, 8 Ethernet Channels, 2 Axis CIP motion with Kinematics function, 24 DC Power. This Controller uses PT. I-O (1734) backplane. Controllers are shipped with 1G
Allen Bradley / PLCs / Point I/O 1734
This input module operates with sinking inputs and supports four separate inputs in one group. It functions effectively at a nominal on-state voltage of 24V DC and can handle a maximum on-state voltage of 28.8V DC. Operating currents range from a minimum of 2 mA to a maximum of 5 mA, allowing for ve
Allen Bradley / PLCs / SLC 500
This is a single-slot module that requires no user programming to operate. It features a status display, along with a FAULT LED and a COMM LED for monitoring purposes. The device's backplane current consumption is rated at 375 mA at 5 Volts DC, and it operates effectively within a temperature range
Allen Bradley / PLCs / Point I/O 1734
This terminal base offers an integrated field power distribution system and is compatible with POINT I/O modules. It supports a rated terminal voltage of up to 300 V and a maximum terminal current of 8 A. The assembly mounts onto a DIN rail and includes a grounding method via the DIN rail. Additiona
Allen Bradley / PLCs / SLC 500
This link coupler enables connections for both full-duplex and half-duplex DH-485 networks. It supports the communication of various devices, including data table axis modules and personal interface converters. Additionally, it can operate in temperatures ranging from 32 to 140 degrees Fahrenheit, w
Allen Bradley / PLCs / Point I/O 1734
This temperature input module accommodates two channels for thermocouple signals. It employs a delta-sigma conversion method and provides high-resolution data at 15 bits. The module operates using POINTbus power and consumes 175 mA to deliver 8 bytes of signed integer output data. Each channel is in
Allen Bradley / PLCs / ControlLogix
This remote I/O module accommodates up to 10 scheduled I/O connections and can manage 32 physical racks. It draws a current of 450 mA at 5.1 volts DC and 5 mA at 24 volts DC. The power dissipation is rated at 2.5 watts along with a thermal dissipation of 8.5 BTU per hour. Continuous isolation voltag