Products

CHF115ST

CHF115ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This unit is a single-pole breaker intended for 1-phase applications. It utilizes a trip flag for indication when a fault occurs and has long-time and instantaneous trip functions for optimal protection. The CHF115ST easily mounts with a plug-on connection for straightforward installation.

Call
CHFN120EP

CHFN120EP

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This breaker features one pole and utilizes thermal-magnetic trip technology. With sensitivity set at 30 mA, it offers both long-time and instantaneous trip functions. It achieves an interrupt rating of 10 kA at 120 V and is suitable for indoor applications. Connection is facilitated through a pigta

Call
CH3100ST

CH3100ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker includes three poles and provides a 10 kA interrupt rating at 240 volts AC. Designed for operation within a frequency range of 50 to 60 Hertz, it supports conductor sizes from 10 AWG to 1/10 AWG. The device uses a 2-position handle for actuation and features a NEMA 3R enclosure.

Call
CHFN115EP

CHFN115EP

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Engineered for safety, the CHFN115EP GFCI provides an interrupt capacity of 10 kAIC. Special features include a 30 mA sensitivity rating for added protection, and pigtail connections facilitate easier installation. The unit is rated for operation in a temperature range from -20 to 60 degrees Celsius

Call
CHN215CAF

CHN215CAF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features a two-pole design with an interrupt rating of 10 kAIC. It utilizes thermal magnetic protection, ensuring both long-time and instantaneous trip functions. The neutral type is a pigtail, and the mounting configuration is plug-in for straightforward installation.

Call
CHN240GF

CHN240GF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features two poles and is designed for single-phase applications. It uses a plug-in connection and integrates both long-time and instantaneous trip functions. It includes a ground fault self-test feature and operates effectively in 80% non-condensing humidity.

Call
CHFN250GF

CHFN250GF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker is designed for single-phase applications and offers a plug-in connection for easy installation. It has an interrupting capacity of 10 kA at 120 V and is sensitive to ground faults and overcurrent, with a sensitivity threshold of 5 mA. It complies with UL standards for safety an

Call
CH230EPD

CH230EPD

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Featuring a common trip mechanism, the CH230EPD ensures coordinated tripping for multiple circuits. This device includes two poles and is equipped with a thermal-magnetic trip unit that protects against thermal overloads as well as ground faults. It is compatible with panelboard and loadcenter mount

Call
CH3080

CH3080

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features a common trip mechanism and is rated with a 10 kAIC interrupting capacity. It is designed specifically for indoor applications, supporting both copper and aluminum conductors. The plug-in installation type simplifies setup within load centers.

Call
CHF230ST

CHF230ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker operates with a commonly used trip type for breaker functionality. It has a frame type identified as CH and is rated for an interrupt capacity of 10 KAIC. The unit is designed for 1-phase systems and provides both long-time and instantaneous protection. The connection type is a

Call