CHF115ST

CHF115ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This unit is a single-pole breaker intended for 1-phase applications. It utilizes a trip flag for indication when a fault occurs and has long-time and instantaneous trip functions for optimal protection. The CHF115ST easily mounts with a plug-on connection for straightforward installation.

Call
CHFN115EP

CHFN115EP

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Engineered for safety, the CHFN115EP GFCI provides an interrupt capacity of 10 kAIC. Special features include a 30 mA sensitivity rating for added protection, and pigtail connections facilitate easier installation. The unit is rated for operation in a temperature range from -20 to 60 degrees Celsius

Call
CHFN120EP

CHFN120EP

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This breaker features one pole and utilizes thermal-magnetic trip technology. With sensitivity set at 30 mA, it offers both long-time and instantaneous trip functions. It achieves an interrupt rating of 10 kA at 120 V and is suitable for indoor applications. Connection is facilitated through a pigta

Call
CH3100ST

CH3100ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker includes three poles and provides a 10 kA interrupt rating at 240 volts AC. Designed for operation within a frequency range of 50 to 60 Hertz, it supports conductor sizes from 10 AWG to 1/10 AWG. The device uses a 2-position handle for actuation and features a NEMA 3R enclosure.

Call
CHN240GF

CHN240GF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features two poles and is designed for single-phase applications. It uses a plug-in connection and integrates both long-time and instantaneous trip functions. It includes a ground fault self-test feature and operates effectively in 80% non-condensing humidity.

Call
CH360ST

CH360ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Designed for 3-phase configurations, the CH360ST circuit breaker features a thermal magnetic protection mechanism. It supports a plug-in connection type and is rated with an AIC of 10 KA at 240 V, ensuring reliable interrupt capability. The device functions effectively in conditions of up to 80% non

Call
CH250EPD

CH250EPD

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

The Eaton Cutler-Hammer CH250EPD GFCI circuit breaker has an interrupting capacity of 10 kAIC. It utilizes a thermal-magnetic trip mechanism, ensuring reliable operation under fault conditions. This breaker accommodates wire sizes from #14 to #6 AWG for copper or aluminum conductors and mounts via a

Call
CHN225GF

CHN225GF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Designed for a temperature range of -35 to 66 degrees Celsius, the CHN225GF GFCI operates efficiently. It possesses a 10 kAIC rating at 240 volts and includes both long time and instantaneous trip functions. This unit utilizes thermal magnetic protection and has a sensitivity of 5 mA. Installation i

Call
CH230EPD

CH230EPD

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Featuring a common trip mechanism, the CH230EPD ensures coordinated tripping for multiple circuits. This device includes two poles and is equipped with a thermal-magnetic trip unit that protects against thermal overloads as well as ground faults. It is compatible with panelboard and loadcenter mount

Call
CH3080

CH3080

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features a common trip mechanism and is rated with a 10 kAIC interrupting capacity. It is designed specifically for indoor applications, supporting both copper and aluminum conductors. The plug-in installation type simplifies setup within load centers.