1878 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Equipped with fixed thermal and fixed magnetic trip units, this circuit breaker provides reliable protection against overloads and short circuits. The interrupting ratings vary based on voltage levels: 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. Constructed t
Eaton Cutler-Hammer / Drives / W200 Drives
This equipment is classified as a size 1C NEMA motor starter and contains three poles. It supports trip class selections of 10, 20, or 30. With horsepower ratings of 7.5 Hp at 230V and 10 Hp at both 460V and 575V, it is versatile for various applications. This starter can be panel mounted either ver
Eaton Cutler-Hammer / Drives / S811 Soft Starters
The S811N66N3L is an open soft starter rated for a maximum current capacity of 66 amps. It features an extended ramp start for smooth motor operation. Designed for versatility, this unit works within a voltage range of 200 to 600 volts and supports an operating frequency of 47 to 63 Hz. It offers 20
Eaton Cutler-Hammer / Drives / S811 Soft Starters
This model features an impressive maximum current capacity of 240 A and is rated for 75 horsepower at 230 volts. The operating frequency falls between 47 to 63 Hz. Shock resistance is rated at 15g, and it includes a bypass with a mechanical lifespan of 10 million cycles. The insulating voltage is Ui
Eaton Cutler-Hammer / Drives / W201 Contactors
This reversing contactor features three poles and is rated for 230 volts. It supports continuous current of up to 90 amps while its maximum horsepower rating stands at 30. The product is categorized under NEMA Size 3 and has dimensions of 3.68 inches in width, 8 inches in height, and 6.49 inches in
Eaton Cutler-Hammer / Drives / S811+ Soft Starters
This non-combination soft starter operates at a maximum of 240 volts AC and 120 volts DC, with an insulating voltage of 660V. The device features three poles and supports an operating frequency from 47 to 63 Hz. The mechanical bypass is rated for a lifespan of 10 million operations and can withstand
Eaton Cutler-Hammer / Drives / S811+ Soft Starters
This non-combination soft starter operates at a maximum of 240 volts AC and 120 volts DC. Rated for 420 amps, the S811+V42V3S accommodates three poles. It withstands insulation voltages of up to 660V and operates within a frequency range of 47 to 63 Hz. The mechanical lifespan of the bypass function
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a voltage rating of 600 Volts AC and 250 Volts DC. It incorporates a 3-pole configuration and is rated for thermal and magnetic protection. With a fixed/bolt-on mounting method, the HFD3030 can accommodate wire sizes from 14 AWG to 1/0 AWG.