1928 results
GE Fanuc Emerson / Series 90-30
This portable programmer supports a diagnostic startup function that self-checks once power is supplied to the PLC. It is configured for I/O hardware setup. Operating temperature ranges from 0°C to 60°C, and it maintains functionality in relative humidity levels between 5% and 95%. The unit can be s
GE Fanuc Emerson / Genius I-O
The GE Fanuc IC660EBA020 Genius I/O Analog Block Electronics Assembly is made for the Genius I/O IC66BBA020 Voltage/Current Analog Block. This I/O block electronics assembly has 4 analog inputs, 2 analog outputs, 18 to 56 Volts DC of operating voltage, and 8.0 Watts of output power.
GE Fanuc Emerson / RX3i PacSystem
This terminal block is structured with a shielded cable connector type, ensuring minimal interference in communication setups. Designed to operate within temperatures ranging from 0 °C to 60 °C, it maintains performance reliability across these conditions. It has been tested for installation at alti
GE Fanuc Emerson / Versamax
This expansion unit features no inputs, providing a dedicated 16 outputs configuration. The output type is sink-type DC transistor, with an output voltage range of 12/24 volts DC. Each point can handle a maximum load of 0.5 amperes, while the total common load is limited to 3 amperes. External fusin
GE Fanuc Emerson / Series Five
This RS-232/RS-422 adaptor supports communication signal isolation and repetition. It boasts a normal link length of 4000 feet for RS-422 connections and a capacity for up to 90 linkable units. Operating conditions allow temperatures from 0 to 60 degrees Celsius and relative humidity levels of 5% to
GE Fanuc Emerson / Field Control
The Field Control IC670MFP100 Micro Field Processor is a specialized Micro PLC unit designed by GE Fanuc. It comes with 6.5 Volts DC of input voltage, 300 milliamps of input current at 24 Volts DC, 6K words of user program storage, and 4 LED indicators.
GE Fanuc Emerson / Series Six
This output module features six outputs, with a maximum on-state current of 3A per output. Leakage when the module is off is recorded at 4 mA. It can withstand a maximum inrush current of 20A for 33 ms, ideal for applications with high starting demands. The module exhibits an average output voltage
GE Fanuc Emerson / Series Six
This output module features 32 TTL output points, each with an individual LED indicator for monitoring status. It supports DIP switch configuration within the PLC's CPU output table and includes options for circuit board jumper configurations, which allow for inversion, disabling, or holding the las