365 results
GE Fanuc Emerson / Spectra
The TED113010 circuit breaker features a single pole configuration and uses a non-interchangeable trip style. It has an interrupting capacity of 14 KAIC at 120 VAC and 10 KAIC at 480 VAC. The breaker supports a fixed long-time trip mechanism and operates within an AC voltage range of 120 to 480 VAC,
GE Fanuc Emerson / Spectra
This circuit breaker features two poles and offers thermal magnetic protection. It has an interrupting capacity of 18 kA at 480 VAC, and it can operate in environments with temperatures ranging from -25 °C to 70 °C. The feed-thru connection design facilitates easy integration into electrical systems
GE Fanuc Emerson / Spectra
This circuit breaker is suitable for 1-phase systems and is designed with a feed-thru connection type. With a mounting type classified as bolt-on, it simplifies installation. It boasts an impressive interrupting rating of 19 kA at 480 VAC and utilizes an LI trip function for overload protection.
GE Fanuc Emerson / Spectra
Specifically engineered for 3-phase applications, this device features 3 poles and a trip mechanism categorized as LI with non-interchangeable thermal magnetic capability. It operates at a voltage rating of 240 VAC and can manage an interrupt rating of 10 kA. The breaker is housed in a black casing
GE Fanuc Emerson / Spectra
This rating plug ensures GSA compliance and is certified by UL and CSA. It functions as a spare part or accessory, with a recommended operating temperature between 0 to 40 degrees Celsius. With storage capabilities extending from 0 to 50 degrees Celsius, it can operate in environments with a maximum
GE Fanuc Emerson / Spectra
Featuring a robust design, this interchange plug is engineered for a three-pole configuration. It supports a trip adjustment range between 1830 and 6075 amperes and is suitable for installation in the field. The product is certified by UL, CSA, and IEC, and operates effectively within a temperature
GE Fanuc Emerson / Spectra
This device features a three-pole configuration and is rated for an interrupting capacity of 200 kAIC at 480 VAC. It is compatible with a 4-wire setup and mounts via a plug-in method. The NEMA 1 enclosure allows for indoor usage. Designed for 3-phase systems, it operates effectively within a frequen
GE Fanuc Emerson / Spectra
This circuit breaker rating plug is compatible with frame types SEDA, SEHA, SELA, and SEPA. It is designed for operational settings with a humidity level of 80% (non-condensing) and functions within a temperature range of 0°C to 40°C. The installation altitude of this unit is limited to 1000 meters
GE Fanuc Emerson / Spectra
Designed for voltage applications of up to 600 Volts AC, this rating plug influences both long time pickup and long time delay scaling in trip logic. The trip range extends from 380 to 1275 Amperes, ensuring flexibility for different operational requirements. This unit is housed in a G Frame and is
GE Fanuc Emerson / Spectra
With a thermal magnetic protection scheme, this circuit breaker features long-time and instantaneous trip capabilities. It has a 35kA AIC rating, ensuring effective fault management. The unit is designed for single-phase applications and utilizes load-side lug terminals for connections, accommodatin