Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

51ML10-E1

51ML10-E1

Honeywell / Micro Switch

This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.

Call
EXH-AR33

EXH-AR33

Honeywell / Micro Switch

The EXH-AR33 model operates at a current rating of 1.0 A and a voltage rating of 125 VAC. It has an operating force ranging from 2.22 N to 6.67 N, and a differential travel of 0.25 mm. This switch is housed in rugged aluminum and has a NEMA rating of 1, 7, and 9. Designed for extreme conditions, it

Call
060-9584-01

060-9584-01

Honeywell / Model 41 Series

Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above

Call
XCDRFDLM

XCDRFDLM

Honeywell / Sensepoint XCD

This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la

Call
060-J912-01

060-J912-01

Honeywell / Model 41 Series

This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s

Call
2108N4110N

2108N4110N

Honeywell / Searchpoint Optima Plus

This gas detector weighs 4.4 lbs and has an IP66 rating, making it suitable for harsh conditions. The operating temperature range extends from -40°C to +65°C, which enhances its versatility. It features a current rating with a maximum inrush of 800 mA at 24VDC and consumes 3.7W of power when using t

Call
2108N4100N

2108N4100N

Honeywell / Searchpoint Optima Plus

This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3

Call
S301-IRF-R410A

S301-IRF-R410A

Honeywell / 301EM Series

This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable

Call
S301-IRF-R134A

S301-IRF-R134A

Honeywell / 301EM Series

The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.

Call
S301-IRF-R514A

S301-IRF-R514A

Honeywell / 301EM Series

This refrigerant gas sensor supports a voltage rating from 8.5 to 12.5 Vdc and operates with a maximum current of 1 A at 10 Vdc. It features an accuracy of ±10 ppm at low concentrations and ±40 ppm at higher levels. The operational environment accommodates temperatures between 0°C and 40°C with a hu

Call
Showing 401-410 of 966 results