404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker supports a trip type of T186 and operates within a frequency range from 50 Hz to 60 Hz. The frame size is categorized as F Frame. With an interrupting capacity of 65 kAIC at 480 V AC and 100 kAIC at 240 V AC, it provides robust protection in electrical circuits.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker includes three poles and is categorized under the K frame type. It employs a T186 trip mechanism that consists of fixed thermal and fixed magnetic protection. The KD3125 can handle an interrupt rating of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featured as part of the Series C line, this 3-pole circuit breaker is suitable for 3-phase applications and includes fixed thermal and magnetic protection. With an interrupt rating of 100 kAIC at 240 Vac, it ensures robust performance under fault conditions. Its terminal configuration allows for fee
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a voltage rating of 600 Volts AC and 250 Volts DC. It incorporates a 3-pole configuration and is rated for thermal and magnetic protection. With a fixed/bolt-on mounting method, the HFD3030 can accommodate wire sizes from 14 AWG to 1/0 AWG.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker includes a 3-pole configuration and is compatible with both AC and DC voltage applications. The AC voltage rating extends up to 600 volts, while the DC rating is capped at 250 volts. Interrupt ratings are notable at 100 kAIC for 240 Vac, 65 kAIC for 480 Vac, and 25 kAIC for 600
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Equipped with fixed thermal and fixed magnetic trip units, this circuit breaker provides reliable protection against overloads and short circuits. The interrupting ratings vary based on voltage levels: 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. Constructed t
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is housed in an F-frame design with a current rating of 25 amperes. It features three poles and adheres to frequency ratings of 50/60 Hz. This circuit breaker offers both fixed thermal and magnetic protection and is equipped with LI trip functionality. Its interrupt ratings are
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for durability, the HFD3030L features a robust F-frame construction and includes three poles, intended for 3-phase connections. With an AC voltage rating of up to 600 volts and a DC rating of 250 volts, it is suitable for diverse electrical setups.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is ideal for AC systems with a rating of up to 600 Volts and accommodates DC applications at 250 Volts. The product provides protection through fixed thermal and magnetic mechanisms and has dual trip functions, including long-time and instantaneous options.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a trip unit that operates on fixed thermal and fixed magnetic principles. It is equipped with an interrupting capacity rated at 65 kAIC for 240 V AC, 35 kAIC for 480 V AC, 25 kAIC for 600 V AC, and 20 kAIC for 250 V DC. Designed for feed-through mounting, the KD3400 has alum