Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-G3C4-D10 from the 140G MCB series.
    Allen Bradley

    140G-G3C4-D10

    This circuit breaker operates with four poles and has a fixed thermal and magnetic trip system. It supports a current range of 100 amps and is built to handle an insulation voltage rating of 800 volts

    Available
    Call
  • 140G-H0C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-H0C3-C70

    The 140G-H0C3-C70 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-H2I3-C25 from the 140G MCB series.
    Allen Bradley

    140G-H2I3-C25

    The 140G-H2I3-C25 Molded Case Circuit Breaker has a Electronic LSIG Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-R12I3-E20-Z1 from the 140G MCB series.
    Allen Bradley

    140G-R12I3-E20-Z1

    This circuit breaker is classified under frame R and features an interrupting rating of 125 kA. It also includes electronic LSIG protection for enhanced safety. The maximum current rating is 2000 A, a

    Available
    Call
  • 140G-H2F3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H2F3-D16

    This circuit breaker is designed with an H frame, supporting a current range of up to 160 Amps. It offers adjustable thermal and magnetic protection mechanisms. The rated insulation voltage is 1000 Vo

    Available
    Call
  • 140G-G6C3-C16 from the 140G MCB series.
    Allen Bradley

    140G-G6C3-C16

    This molded case circuit breaker has three poles and accommodates a current range of 16 amps. It offers robust protection with a thermal trip setting at 16 amps and a magnetic trip threshold of 500 am

    Available
    Call
  • 140G-H2H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-H2H4-D10

    This four-pole molded case circuit breaker utilizes electronic LSI protection. It supports a maximum current of 100 A and operates efficiently with a rated insulation voltage of 1000 V. The unit can w

    From $927
    Available
  • 140G-G3C4-C60 from the 140G MCB series.
    Allen Bradley

    140G-G3C4-C60

    The 140G-G3C4-C60 is a molded case circuit breaker designed for reliable performance in various electrical systems. With a frame type designated as G, it operates at a maximum current of 125 Amps. Thi

    Available
    Call
  • 140G-HC6X3 from the 140G MCB series.
    Allen Bradley

    140G-HC6X3

    This circuit breaker features a HC frame and is rated for a voltage of 1000V. It does not specify a current range other than the frame, and is designed to handle impulse voltages of 8 kV. Weighing 2.6

    Available
    Call
  • 140G-J0F3-D12 from the 140G MCB series.
    Allen Bradley

    140G-J0F3-D12

    The 140G-J0F3-D12 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

    Available
    Call
Showing 231-240 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.