Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H15C4-C30 from the 140G MCB series.
    Allen Bradley

    140G-H15C4-C30

    The 140G-H15C4-C30 circuit breaker includes four poles and operates within a current range of 30 Amps. It offers a rated insulation voltage of 1000 V and can withstand impulse voltages up to 8 kV. Add

    Available
    Call
  • 140G-H15C4-C60 from the 140G MCB series.
    Allen Bradley

    140G-H15C4-C60

    This Allen Bradley molded case circuit breaker, 140G-H15C4-C60, is built with a frame type H and supports up to four poles. It manages a current range of 60 A and boasts an outstanding interrupting ra

    Available
    Call
  • 140G-HC0C3-C20 from the 140G MCB series.
    Allen Bradley

    140G-HC0C3-C20

    This device offers a current range of 20 A and a rated insulation voltage of 1000 V, optimizing its performance in numerous applications. Additional features include a rated impulse withstand voltage

    Available
    Call
  • 140G-HTH3-D12 from the 140G MCB series.
    Allen Bradley

    140G-HTH3-D12

    This molded case circuit breaker includes an HC frame and is rated for 120 A operation. It is designed for electrical applications requiring insulation up to 1000 V and can withstand impulse voltages

    Available
    Call
  • 140G-J6F4-D16 from the 140G MCB series.
    Allen Bradley

    140G-J6F4-D16

    This molded case circuit breaker is rated for a 160 Amp current range and consists of four poles. It provides adjustable thermal and magnetic protection features. The device supports rated insulation

    From $4,867
    Available
  • 140G-G2C4-C90 from the 140G MCB series.
    Allen Bradley

    140G-G2C4-C90

    The Allen Bradley 140G-G2C4-C90 circuit breaker is categorized within the 140G MCB series and is designed with a G frame structure. It operates at 125 Amps and features four poles while providing an i

    Available
    Call
  • 140G-G6C4-C35 from the 140G MCB series.
    Allen Bradley

    140G-G6C4-C35

    This four-pole circuit breaker employs fixed thermal and magnetic protection mechanisms. It supports a rated current of 35 Amps and offers an insulation voltage rating of 800 V. The device is designed

    Available
    Call
  • 140G-H0C4-C63 from the 140G MCB series.
    Allen Bradley

    140G-H0C4-C63

    This molded case circuit breaker, designated 140G-H0C4-C63, features an H frame structure. It is capable of handling a continuous current of 125 Amps with a notable interrupting capacity of 100 kA. De

    Available
    Call
  • 140G-H15C4-C16 from the 140G MCB series.
    Allen Bradley

    140G-H15C4-C16

    The 140G-H15C4-C16 is a highly efficient molded case circuit breaker. Designed with a four-pole configuration, it supports up to 125 amps. The unit incorporates both fixed thermal and magnetic trip me

    Available
    Call
  • 140G-J6F3-C90 from the 140G MCB series.
    Allen Bradley

    140G-J6F3-C90

    This breaker operates within a current range of 90 A and is designed with adjustable thermal and magnetic protection features. It can withstand a rated insulation voltage of 1000 V and impulse voltage

    From $3,645
    Available
Showing 341-350 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.