Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-M5H4-D60 from the 140G MCB series.
    Allen Bradley

    140G-M5H4-D60

    The 140G-M5H4-D60 features four poles and is rated for a current range of up to 600 Amps. It is rated for impulse withstand voltages of 8 kV. This breaker weighs 33.29 pounds and is designed for mecha

    Available
    Call
  • 140G-KC6F3-D40 from the 140G MCB series.
    Allen Bradley

    140G-KC6F3-D40

    Incorporating adjustable thermal and magnetic protection types, the 140G-KC6F3-D40 ensures reliable operation for diverse applications. Its rated insulation voltage is 1000 volts and it withstands imp

    Available
    Call
  • 140G-ELBU from the 140G MCB series.
    Allen Bradley

    140G-ELBU

    Designed to fit specific frame sizes, the 140G-ELBU operates effectively from 0 °C to 40 °C. It features a convenient push button for battery checks and an LED indicator to monitor battery charge stat

    From $1,212
    Available
  • 140G-G3C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-G3C4-C40

    The 140G-G3C4-C40 is a four-pole molded case circuit breaker rated at 125 Amps. It features fixed thermal and magnetic protection options with a current range of 40 Amps. The device handles an interru

    Available
    Call
  • 140G-G6C4-C50 from the 140G MCB series.
    Allen Bradley

    140G-G6C4-C50

    This model is equipped with both fixed thermal and magnetic protections, with a thermal trip set at 50 amps and magnetic trip at 500 amps. Operating with a rated insulation voltage of 800 volts and an

    Available
    Call
  • 140G-G6C4-C70 from the 140G MCB series.
    Allen Bradley

    140G-G6C4-C70

    This model, part number 140G-G6C4-C70, is a 4-pole molded case circuit breaker with a G frame structure. It provides a thermal trip rating of 70 Amps and a high magnetic trip setting of 700 Amps. With

    Available
    Call
  • 140G-H0I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H0I3-C60

    This molded case circuit breaker has a current range of 60 A and is equipped with electronic LSIG protection. It can handle a rated insulation voltage of 1000 V, while the rated impulse withstand volt

    Available
    Call
  • 140G-H2F4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H2F4-D16

    This circuit breaker features four poles and supports an adjustable thermal and magnetic trip mechanism. The maximum current range is set at 160 Amps. It also provides a rated insulation voltage of 10

    From $1,176
    Available
  • 140G-G3E4-D16 from the 140G MCB series.
    Allen Bradley

    140G-G3E4-D16

    This molded case circuit breaker supports an adjustable thermal protection mechanism alongside fixed magnetic protection. The 140G-G3E4-D16 model operates within a current range of 160 Amps and has a

    Available
    Call
  • 140G-G6C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-G6C4-C40

    This circuit breaker functions within a frame size classified as G and offers four poles for effective management. The thermal trip rating is set at 40 Amps, while the magnetic trip is rated for 500 A

    Available
    Call
Showing 351-360 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.