140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H0I3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H0I3-D16

    This circuit breaker operates with a rated current range up to 160 A and provides an insulation voltage rating of 1000 volts. It withstands impulse voltages of up to 8 kV. Weighing in at 2.65 lb, it o

    Available
    Call
  • 140G-H6C4-C32 from the 140G MCB series.
    Allen Bradley

    140G-H6C4-C32

    This model features four poles and operates within a current range of 32 A. It boasts a rated insulation voltage of 1000 V and can withstand impulse voltages of up to 8 kV. Weighing 3.53 pounds, it is

    Available
    Call
  • 140G-N0H3-E12-Z1 from the 140G MCB series.
    Allen Bradley

    140G-N0H3-E12-Z1

    This model qualifies as a frame N circuit breaker and operates efficiently within a rated insulation voltage of 1000 volts. It can withstand impulse voltages of 8 kV, ensuring durability during transi

    Available
    Call
  • 140G-I2C3-D16 from the 140G MCB series.
    Allen Bradley

    140G-I2C3-D16

    This molded case circuit breaker features a frame size of I and operates effectively within a current range of 160 A. Its rated insulation voltage is 800 V, while the impulse withstand voltage is rate

    Available
    Call
  • 140G-JTH3-D25 from the 140G MCB series.
    Allen Bradley

    140G-JTH3-D25

    This circuit breaker operates within the JC frame type and has a rated insulation voltage of 1000 volts. It also features an impulse withstand rating of 8 kV. The device weighs 5.51 pounds and support

    Available
    Call
  • 140G-J6C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J6C3-C60

    This device can handle a current range of 60 A while maintaining a rated insulation voltage of 1000 volts. It also withstands impulse voltages of 8 kV. Weighing 5.51 pounds, the mechanical life rating

    Available
    Call
  • 140G-G3C4-C45 from the 140G MCB series.
    Allen Bradley

    140G-G3C4-C45

    The 140G-G3C4-C45 model is a molded case circuit breaker featuring a G-frame design. It operates with an amperage capacity of 125 Amps and has an interrupting rating of 35 kA. Designed for 4-pole conf

    Available
    Call
  • 140G-H0H3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H0H3-D16

    This circuit breaker operates within an H-frame and supports a current range of 160 amps. It employs electronic LSI protection, ensuring efficient operation and safety. The unit can manage insulation

    Available
    Call
  • 140G-H15C3-C16 from the 140G MCB series.
    Allen Bradley

    140G-H15C3-C16

    This molded case circuit breaker is designed for high performance with a rated current of 125 amps and an interrupting capacity of 150 kA. It features fixed thermal and magnetic trip mechanisms and op

    Available
    Call
  • 140G-H15C3-C30 from the 140G MCB series.
    Allen Bradley

    140G-H15C3-C30

    The 140G-H15C3-C30 circuit breaker features fixed thermal and magnetic protection. This protective device operates within a current range of 30 A. It provides insulation protection rated at 1000 V and

    Available
    Call
Showing 331-340 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.