140G-JTF3-D25
This molded case circuit breaker features a JC frame type. The 140G-JTF3-D25 operates within a current range of 250 Amps. It supports a rated insulation voltage of 1000 V and is capable of withstandin
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This molded case circuit breaker features a JC frame type. The 140G-JTF3-D25 operates within a current range of 250 Amps. It supports a rated insulation voltage of 1000 V and is capable of withstandin
The 140G-G2C4-C45 is a molded case circuit breaker designed for efficient electrical protection. It features a frame type G, supporting a nominal current of 125 amps and accommodating a current range
This molded case circuit breaker features four poles and is equipped with both fixed thermal and fixed magnetic protection mechanisms. It provides a significant interrupting capacity of 35 kA, with a
This molded case circuit breaker operates at a current range of 100 A and provides an insulation voltage rating of 1000 V. The electrical performance is enhanced with a rated impulse withstand voltage
Designed with an H frame, this circuit breaker operates with a fixed thermal and fixed magnetic protection mechanism. It handles a current range of 32 A and has a rated insulation voltage of up to 100
The 140G-H15F3-C80 model features adjustable thermal and magnetic protection types, with a current range capable of handling up to 80 Amps. It supports a rated insulation voltage of 1000 volts and an
With four poles, this circuit breaker operates within a current range of 200 Amps. It includes fixed thermal and magnetic trip mechanisms for robust protection. Rated for 800 volts of insulation and 8
This testing device is optimized for frequencies between 50 Hz and 60 Hz. Designed as a battery-powered unit, it offers convenient operation wherever needed. It can perform in both storage and operati
The 140G-G2E4-D16 is a molded case circuit breaker designed with a G frame and supports 125 amps. Its interrupting rating is set at 25 kA, while it contains four poles to effectively manage current. T
Designed with an H frame, the 140G-H0F4-D10 includes four poles and adjusts for both thermal and magnetic protection. It is rated for a maximum current range of 100 A. Additional specifications includ
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.