The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-M5K4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M5K4-D63

    Designed for versatility, this breaker has an electronic LSIG protection mechanism and features four poles. It supports a current range up to 630 A and has a rated insulation voltage of 1000 volts. It

    Available
    Call
  • 140G-H2C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-H2C4-C40

    This four-pole circuit breaker operates within a specified current range of 40 A, employing fixed thermal and fixed magnetic trip mechanisms for enhanced reliability. With a rated insulation voltage o

    From $1,110
    Available
  • 140G-G3C4-C70 from the 140G MCB series.
    Allen Bradley

    140G-G3C4-C70

    The 140G-G3C4-C70 circuit breaker is characterized by its 4-pole design and fixed thermal and magnetic protection types. It effectively manages a maximum current range of 70 Amps, with a thermal trip

    Available
    Call
  • 140G-G6C4-C16 from the 140G MCB series.
    Allen Bradley

    140G-G6C4-C16

    This circuit breaker, the 140G-G6C4-C16, is designed with four poles and operates effectively with a current range starting at 16 A. It utilizes fixed thermal and magnetic trip mechanisms, ensuring de

    Available
    Call
  • 140G-H0C3-C16 from the 140G MCB series.
    Allen Bradley

    140G-H0C3-C16

    This molded case circuit breaker operates at an interrupting rating of 100 kA and is built with a frame type H. It includes fixed thermal and magnetic protection, operating in a current range of 16 Am

    Available
    Call
  • 140G-H0C3-C32 from the 140G MCB series.
    Allen Bradley

    140G-H0C3-C32

    This unit is classified under the H-frame and supports a current range of up to 32 Amps. With an impressive interrupting capacity of 100 kA, it ensures effective protection against short circuits. The

    Available
    Call
  • 140G-HTF3-D10 from the 140G MCB series.
    Allen Bradley

    140G-HTF3-D10

    Designed for use in critical electrical control environments, the 140G-HTF3-D10 circuit breaker operates within a maximum current range of 100 A. It has a rated insulation voltage of 1000 V and can wi

    From $272
    In Stock Ships Today
  • 140G-JC0F3-D11 from the 140G MCB series.
    Allen Bradley

    140G-JC0F3-D11

    This circuit breaker operates within a current range of up to 110 A and features adjustable thermal and magnetic protection types. Rated for 1000 volts, it is equipped to withstand impulse voltages of

    Available
    Call
  • 140G-K0F4-D30 from the 140G MCB series.
    Allen Bradley

    140G-K0F4-D30

    This breaker model includes four poles and offers adjustable thermal and magnetic protection mechanisms. It operates at 300 amps of rated current and is rated for 1000 volts of insulation voltage. Cap

    Available
    Call
  • 140G-N6I3-E12-Z1 from the 140G MCB series.
    Allen Bradley

    140G-N6I3-E12-Z1

    Rated for 1200 Amps, this device features an interrupting rating of 60 kA and operates within a rated insulation voltage of 1000 volts. Its impulse withstand voltage is up to 8 kV. The design weighs 2

    Available
    Call
Showing 371-380 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.