140G-J0F4-D12
Designed with an amp rating of 250, the 140G-J0F4-D12 handles a current range of up to 120 A. It has a rated insulation voltage of 1000 volts and a withstand voltage rating of 8 kV. The device weighs
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
Designed with an amp rating of 250, the 140G-J0F4-D12 handles a current range of up to 120 A. It has a rated insulation voltage of 1000 volts and a withstand voltage rating of 8 kV. The device weighs
This circuit breaker model features electronic LSI protection technology and operates with a rated current of up to 150 A. It supports a rated insulation voltage of 1000 V and can withstand impulse vo
The 140G-J0I3-D10 circuit breaker is built with a J frame design and operates with a rated current of up to 100 A. Its rated insulation voltage is 1000 V, with an impressive impulse withstand voltage
The 140G-J0I4-C60 circuit breaker has four poles and operates with a rated current of up to 60 A. It can support insulation voltage levels of up to 1000 V and impulse withstand voltages of up to 8 kV.
This breaker model has a J frame type and features a current rating of 100 A. It supports 250 A of maximum current and a 25 kA interrupting rating. Its rated insulation voltage is 1000 volts, and its
This circuit breaker has a fixed thermal and fixed magnetic protection system. It effectively manages 25 A of rated current and 250 A of maximum current. It features a rated insulation voltage of 1000
This circuit breaker has a J frame and supports four poles. The device operates with 32 Amps of rated current and has a rated insulation voltage of 1000 volts. With an impulse withstand capacity of 8
This specific unit operates within a current range of 25 Amps and has an insulation voltage of up to 1000 volts. It is also rated for an impulse withstand voltage of 8 kV, enhancing its resilience aga
This circuit breaker operates with an adjustable thermal and magnetic protection type. It has four poles and manages a current range of 200 A. Furthermore, it offers rated insulation voltage of 1000V
This model, part of the 140G series, operates with fixed thermal and magnetic protection types. Supporting a current capacity of 50 Amps, it operates efficiently at a rated insulation voltage of 1000
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.