140G-H3I4-C25
The 140G-H3I4-C25 is equipped with electronic LSIG protection. It includes four poles and a current range of 25 Amps. Operating at a rated insulation voltage of 1000 volts and an impulse withstand vol
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
The 140G-H3I4-C25 is equipped with electronic LSIG protection. It includes four poles and a current range of 25 Amps. Operating at a rated insulation voltage of 1000 volts and an impulse withstand vol
This circuit breaker is designed with an H frame structure and features both fixed thermal and fixed magnetic protection types. It can accommodate a current range of up to 63 A and has a rated insulat
This circuit breaker features a four-pole configuration and operates within a current range of 15 A. It is designed with fixed thermal and fixed magnetic protections to enhance safety. With a rated in
The 140G-HC0H3-D10 circuit breaker operates with a current range up to 100 amps. This model employs electronic LSI protection, achieving rated insulation voltage ratings of 1000 volts and a withstand
Equipped with electronic LSI protection, the 140G-HC0H3-D12 supports a current range of up to 120 A. It maintains a rated insulation voltage of 1000 V and can withstand impulse voltages up to 8 kV. We
This unit is designed with a 4-pole configuration and offers a current range of up to 90 A. It supports a rated insulation voltage of 1000 V and features an impressive impulse withstand voltage of 8 k
This circuit breaker features a four-pole configuration and includes both fixed thermal and magnetic protection types. It is rated for insulation voltage up to 800 volts and can withstand impulse volt
This model is equipped with 4 poles and is capable of interrupting currents at a staggering 100 kA level. Designed for a current range of 60 A, it provides reliable protection against faults. The rate
This model operates within a current range of 100 A and includes adjustable thermal and magnetic protection. Designed to withstand insulation voltage ratings of 1000 V and impulse withstand voltages u
This circuit breaker is engineered with a J frame and incorporates four poles. It offers adjustable thermal and magnetic protection, suited for various applications. Its current range is rated at 100
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.