Free UPS Ground on All Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-J3F4-C80

Designed with a J frame, the 140G-J3F4-C80 model demonstrates adjustable thermal and magnetic protection types. Its current range is rated at 80 Amps, while it supports insulation rated up to 1000 Vol

Call
4.4

140G-J3F4-D22

This device incorporates four poles and is engineered to manage a current range up to 220 A. It can withstand insulation voltages of 1000V and impulse withstand voltages of 8 kV. Weighs 7.72 pounds, i

Call
4.7

140G-J3I3-D15

This device is categorized under the J frame and provides an interrupting capacity of 35 kA. The breaker operates within a current range of 150 A, with a rated insulation voltage of 1000 V. It withsta

Call
4.7

140G-J3X4

This unit supports a four-pole configuration and operates at a rated insulation voltage of 1000 volts. Its impulse withstand voltage reaches 8 kV, ensuring reliability in harsh conditions. Weighing in

Call
4.8

140G-J6C4-C40

This circuit breaker features four poles and operates within a current range of 40 Amps. Its insulation voltage is rated at 1000 volts. The circuit breaker can withstand impulse voltages of up to 8 kV

Call
5.0

140G-J6F4-C90

A key feature of the 140G-J6F4-C90 is its adjustable thermal and magnetic protection settings. With a four-pole configuration, it can handle currents up to 90 Amps. The device supports a rated insulat

Call
4.9

140G-J6I4-D10

This version is designed with four poles and supports a current range of up to 100 A. The rated insulation voltage is 1000 V, offering flexibility in various conditions. In addition, it can withstand

Call
4.5

140G-JC0F3-C80

This circuit breaker operates in an 80 A current range and boasts an impressive rated insulation voltage of 1000 volts. It can withstand impulse voltages of up to 8 kV. With a weight of 5.51 pounds, i

Call
4.8

140G-JC6C3-C63

This circuit breaker model provides a rated insulation voltage of 1000 volts. It is equipped with a 63 A current range and incorporates multiple features for stable operation. Weighing 5.51 pounds, it

Call
4.7

140G-JC6F3-D16

This device operates at a current range of 160 A while providing adjustable thermal and magnetic protection for enhanced safety. It supports a rated insulation voltage of up to 1000 volts and can with

Call
4.9
Showing 951-960 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.