Free UPS Ground on All Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer W200 Drives Repair

Eaton Cutler-Hammer W200 Drives Repair

We offer extensive repairs for your W200 Drives. We keep many spare parts in stock so that we can repair your W200 Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your W200 Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse W200 Drives Repairs

Browse our catalog of repairable W200 Drives parts to get a quote.

W+200M2CFC

This motor starter adheres to NEMA Size 2 standards and features a current capacity of 45 A. It is designed to function within a frequency range of 50 to 60 Hz. The model supports multiple horsepower

In Stock Ships Tomorrow

W200M1CFC

The W200M1CFC Cutler Hammer is a NEMA Contactor/Starter Eaton Drive. It belongs to the W200 series and has a motor voltage of 200 with a maximum hp of 1. Its enclosure must be size 1 and its coil volt

Call

W200M1CNC

This non-reversing starter is rated for a maximum horsepower of 7.5 at three-phase configurations. Its temperature operating range extends from 0 to 40°C, and it maintains functionality in relative hu

Call

W200M2CFC

The W200M2CFC Cutler Hammer is a NEMA Contactor/Starter Eaton Drive. It belongs to the W200 series and has a motor voltage of 200 with a maximum hp of 1. Its enclosure must be size 1 and its coil volt

In Stock Ships Today

W200M2CNC

This starter features a coil voltage range from 110 to 120 volts. With an enclosure rated to NEMA 3 standards, it is equipped to handle conditions requiring moisture resistance. The device functions r

Call

W200M3CFC

This motor control starter is rated for 3 poles and has a frequency rating of 60 Hz. It falls under NEMA size 1C and includes standard overload protection for enhanced reliability. The starter is desi

Call

W200M3CNC

The W200M3CNC features three poles compatible with NEMA Size 3 specifications and operates at a coil voltage of 110 VAC, 50 Hz. It supports an input phase of 3-phase power and has a continuous current

Call

W200M4CFC

This motor starter is classified as non-reversing and belongs to NEMA size 4, ensuring durability in various conditions. It can handle operational altitudes up to 2000 meters and operates effectively

Call

W200M4CNC

This unit is classified as a size 4 NEMA starter, accommodating operating temperatures from 32°F to 104°F. With a coil voltage of 110V AC and a frequency specification of 50 Hz, it is efficient for in

Call

W200M5CFC

This NEMA size 5 contactor operates with a continuous current rating of 270 A and supports starter motor horsepower ratings up to 200 Hp at both 460 V and 575 V. It accommodates a frequency range from

Call
Showing 1-10 of 43 results

About W200 Drives

Eaton Cutler-Hammer W200 non-reversing magnetic servo motor starters are full-voltage servo motor starters that are made for supplying and interrupting power to the motors due to the command signals or for interrupting motor power due to the activation of some of the protective functions. The states recognized by W200 servo motor starters as a danger to the motors are ground currents, phase losses, phase imbalances, or significant overloads. In all the above cases, the W200 servo motor starters will cut off the power to the motors and the LED that indicates the “trip” position will light up. These devices cannot be restarted until a reset procedure is performed, and this can be done manually (push the reset button on the starter housing) or remotely. At the bottom of the W200 starters are a DIP switch that is used to select the device’s reset mode, overload class, and the overload limit current. Based on the setting on the DIP switch, the starters can be calibrated to detect currents in the range of 12.4 to 111 Amps.

The Eaton W200 servo motor starters can be size 3 or size 4 and these sizes can cover 25 to 100 Horsepower (20 to 75 kilowatts) rated 3-phase motors. The main part of the W200 servo motor starters is the circuit board holding microprocessor that is programmable and responsible for all the devices’ protective features. Two communication devices known as WPONI and WPONIDNA devices can be added to the basic version of the W200 servo motor starters. The WPONI device is used for remote control and it allows the microprocessor to send data at 9600 baud rate via the INCOM network. The WPONIDNA adapter allows for device control via the DeviceNet network at a 125,000 baud rate.