Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley Panelview 550 Repair

Allen Bradley Panelview 550 Repair

We offer extensive repairs for your Panelview 550. We keep many spare parts in stock so that we can repair your Panelview 550 as efficiently and effectively as possible. Our standard repair lead time is 3-5 days. However, we can often repair your unit much faster if necessary. We can repair most issues with your Panelview 550 and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your Panelview 550 parts.

Browse Panelview 550 Repairs

Browse our catalog of repairable Panelview 550 parts to get a quote.

2711-K5A16L1X

Featuring keypad input, this model includes 10 function keys available for user interaction. The terminal operates on an input voltage range from 18 to 32 VDC and has a versatile memory capacity that

In Stock Ships Today

2711-K5A16X

With a display area measuring 120 x 60 mm and a resolution of 256 x 128, this unit provides a clear and easy-to-read interface. The keypad comprises ten function keys (F1 to F10), allowing for straigh

In Stock Ships Today

2711-K5A1L1X

This operator interface utilizes a monochrome display with a size of 5.5 inches and 256 x 128 resolution. It operates effectively at an input voltage of 24V DC, with a maximum power consumption of 45

Call

2711-K5A1L2X

This operator interface module operates at an input voltage range of 85 to 264V AC and functions within a frequency of 47 to 63 Hz. It has a display area measuring 120 x 60 mm (4.75 x 2.38 in.), ideal

Call

2711-K5A1X

This operator terminal integrates a keypad input method with ten function keys (F1 to F10) for streamlined operations. It features communication capabilities for Remote I/O and has an RS-232 port for

Call

2711-K5A2

This interface terminal features monochrome graphics with a pixel resolution of 256 by 128, making it effective for displaying relevant information. Its operating conditions allow for a temperature ra

In Stock Ships Today
Showing 71-80 of 136 results

About Panelview 550

The Panelview 550 terminal series is a series of high-performance operator terminal manufactured by Allen-Bradley. These high-performance operator terminals are designed to meet the users’ needs, with a space-saving construction and a flat panel design. The Panelview 550 series terminals come with the monochrome screens, with the keypad/touchscreen input option combination. The screen size is 5.5 inches diagonal and it is an LCD monochrome display with a pixel resolution of 256 x 128. The Panelview 550 touch-only operator interface terminals feature a 30% smaller size. The Panelview 550 terminals come with 10 functional keys and numeric keypads. The terminals feature cursor control keys and 3.4 inches of installed depth. The Panelview 550 terminals feature a voltage supply of 85 to 264 Volts AC and 47 to 63 Hertz. The power consumption is 45 VA maximum.

The Panelview 550 terminals should be installed in well-protected environments to ensure optimal performance. When installing the Panelview 550 terminals, use a panel or enclosure to protect the internal circuitry. The standard operator interfaces feature indoor use ratings only and they should be properly mounted in panels or enclosures with equivalent ratings. During installation, ensure that there is enough space within the enclosure to ensure that there is adequate ventilation and to prevent overheating. The heat that is produced by other devices can result in overheating, affecting the functionality of these terminals. The ambient operating temperature range around the Panelview 550 terminals should be 0 to 55 degrees Celsius. Ensure that there is a provision for accessing the back panel of the terminals to support wiring, device maintenance, and the installation of a memory card as well as easy troubleshooting.

Common Errors Codes that we repair for the Panelview 550 (2711-K5, 2711-B5, and 2711-T5):

  • Error 1 STATIC RAM test
  • Error 2 Terminal searching for a file to download.
  • Error 10 Erase boot flash area.
  • Error 11 Copy boot code
  • Error 12 Boot code copy successful
  • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
  • Error 31 Stuck key test
  • Error 32 Real time clock test
  • Error 33 LCD RAM failed
  • Error 50 Wrong memory card format
  • Error 60 CPU could not execute code